THE MAGNETIC-RESONANCE RENOGRAM IN RENAL-TRANSPLANT EVALUATION USING DYNAMIC CONTRAST-ENHANCED MR-IMAGING

被引:39
作者
SHARMA, RK
GUPTA, RK
POPTANI, H
PANDEY, CM
GUJRAL, RB
BHANDARI, M
机构
[1] SANJAY GANDHI POSTGRAD INST MED SCI,DEPT RADIOL,LUCKNOW 226014,UTTAR PRADESH,INDIA
[2] SANJAY GANDHI POSTGRAD INST MED SCI,DEPT BIOSTAT,LUCKNOW 226014,UTTAR PRADESH,INDIA
[3] SANJAY GANDHI POSTGRAD INST MED SCI,DEPT UROL,LUCKNOW 226014,UTTAR PRADESH,INDIA
关键词
D O I
10.1097/00007890-199505270-00008
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
To assess the role of the dynamic gadolinium DTPA (Gd-DTPA) magnetic resonance (MR) renogram differentiating various causes of renal allograft dysfunction, contrast-enhanced MR imaging studies were performed in 5 normal renal allografts, 5 patients with acute rejection (AR), and 7 patients with cyclosporine nephrotoxicity. Time-versus-signal intensity (SI) curves were plotted. Normal renal allografts showed a rapid increase and slow decay, with a definite peak in cortical (CX) SI curves (peak mean signal intensity (Amax 338.6+/-46.5). The outer medullary (OM) (Amax 306.5+/-59) and inner medullary (IM) (Amax 263.4+/-47.4) curves did not show a definite peak. The OM curve slowly reached a steady state and caught up with the CX curve. AR episodes were characterized by a blunted uprise and delayed peak of CX (Amax 180+/-70.9) and a low-amplitude vascular phase with a slow constant uprise of the inner medullary curve (Amax 120.35+/- 42.4). The OM signal intensity curve (Amax 150.73+/-78) failed to catch up with the CX curve. The maximum amplitude of SI curves in CsA-induced allograft dysfunction were low, with no definite peak, and CX, OM, and TM curves ran parallel to each other with a constant gap. Dynamic Gd-DTPA, MR imaging is a noninvasive technique that shows distinct characteristics in acute rejection, cyclosporine nephrotoxicity, and normally functioning renal allografts.
引用
收藏
页码:1405 / 1409
页数:5
相关论文
共 7 条
[1]   USE OF GD-DTPA AND FAST GRADIENT-ECHO AND SPIN-ECHO MR IMAGING TO DEMONSTRATE RENAL-FUNCTION IN THE RABBIT [J].
CARVLIN, MJ ;
ARGER, PH ;
KUNDEL, HL ;
AXEL, L ;
DOUGHERTY, L ;
KASSAB, EA ;
MOORE, B .
RADIOLOGY, 1989, 170 (03) :705-711
[2]   DYNAMIC GD-DTPA - ENHANCED MR IMAGING OF THE KIDNEY - EXPERIMENTAL RESULTS [J].
CHOYKE, PL ;
FRANK, JA ;
GIRTON, ME ;
INSCOE, SW ;
CARVLIN, MJ ;
BLACK, JL ;
AUSTIN, HA ;
DWYER, AJ .
RADIOLOGY, 1989, 170 (03) :713-720
[3]  
DEWEY C, 1990, CONTRAST MEDIA MRI P, P341
[4]   FUNCTIONAL MR OF THE KIDNEY [J].
FRANK, JA ;
CHOYKE, PL ;
AUSTIN, HA ;
GIRTON, ME .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :319-323
[5]  
KRESTN G, 1990, CONTRAST MEDIA MRI, P327
[6]  
MAGRE G, 1993, P SOC MAGN RES MED, P339
[7]  
SCHUMANNGIAMPIE.G, 1990, CONTRAST MEDIA MRI P, P313