A low-cost tungsten filament atomizer for measuring lead in blood by atomic absorption spectrometry

被引:58
作者
Parsons, PJ
Qiao, HC
Aldous, KM
Mills, E
Slavin, W
机构
[1] SUNY ALBANY,SCH PUBL HLTH,DEPT ENVIRONM HLTH & TOXICOL,ALBANY,NY 12201
[2] BONAIRE TECHNOL,RIDGEFIELD,CT 06877
关键词
blood; electrothermal atomic absorption spectrometry; lead; tungsten coil atomizer;
D O I
10.1016/0584-8547(95)01416-0
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A low-cost electrothermal atomic absorption spectrometry (AAS) system based on a tungsten filament atomizer is proposed for the measurement of blood lead. Preliminary experiments have been carried out using a tungsten filament enclosed in a glass cell, purged with argon and 10% H-2, and mounted on the optical bench of a commercial atomic absorption spectrometer with continuum background correction. The tungsten filament is ballistically heated with a 12 V d.c. power supply. A number of parameters, including filament position, gas flow, drying, pyrolysis and atomization steps, are optimized specifically for blood lead. Peak absorbance is the measurement mode used because of the very fast signals observed. The atomizer is calibrated with aqueous lead standards, and the calibration verified by analyzing blood lead reference materials from NIST, CDC and NYS, that cover the clinical range for blood lead (5-54 mu g dl(-1)). Results below 40 mu g dl(-1) are within +/-2 mu g of the certified value, and within +/-10% of the certified value above 40 mu g dl(-1), indicative of good accuracy especially at the lower blood lead levels. Blood is prepared by diluting 1 + 9 with modifier. Ten microliters of diluted blood is deposited on the filament using a micropipet. Forty-two human blood specimens covering the range 3-31 mu g dl(-1) are analyzed in parallel with a well established graphite furnace AAS method. There is good agreement between the two AAS methods, and the differences between individual paired blood lead results are less than +/-4 mu g. The sensitivity or characteristic (m(0)) of the tungsten filament atomizer is 26 pg, and the method detection limit (3 SD) is about 2 mu g dl(-1).
引用
收藏
页码:1475 / 1480
页数:6
相关论文
共 10 条
[1]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[2]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY [J].
GINE, MF ;
KRUG, FJ ;
SASS, VA ;
REIS, BF ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :243-245
[3]  
LETOURNEAU GG, 1988, AM IND HYG ASSOC J, V49, P342, DOI 10.1202/0002-8894(1988)049<0342:BLAMUE>2.0.CO
[4]  
2
[5]   MONITORING HUMAN EXPOSURE TO LEAD - AN ASSESSMENT OF CURRENT LABORATORY PERFORMANCE FOR THE DETERMINATION OF BLOOD LEAD [J].
PARSONS, PJ .
ENVIRONMENTAL RESEARCH, 1992, 57 (02) :149-162
[6]   A RAPID ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRIC METHOD FOR THE DETERMINATION OF LEAD IN BLOOD [J].
PARSONS, PJ ;
SLAVIN, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (6-7) :925-939
[7]   HORIZONTAL TUNGSTEN COIL ATOMIZER AND INTEGRATED ABSORBANCE READOUT FOR ATOMIC-ABSORPTION SPECTROMETRY [J].
REID, RD ;
PIEPMEIER, EH .
ANALYTICAL CHEMISTRY, 1976, 48 (02) :338-341
[8]   DETERMINATION OF BARIUM IN WATERS BY TUNGSTEN COIL ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
SILVA, MM ;
SILVA, RB ;
KRUG, FJ ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) :861-865
[9]   A NEW BACKGROUND-CORRECTION METHOD FOR ATOMIC-ABSORPTION SPECTROMETRY [J].
SMITH, SB ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1983, 37 (05) :419-424
[10]   COMMERICAL TUNGSTEN FILAMENT ATOMIZER FOR ANALYTICAL ATOMIC SPECTROMETRY [J].
WILLIAMS, M ;
PIEPMEIER, EH .
ANALYTICAL CHEMISTRY, 1972, 44 (07) :1342-+