AN INTERCOMPARISON OF 2 CHAMBER METHODS FOR THE DETERMINATION OF EMISSION OF NITRIC-OXIDE FROM SOIL

被引:25
作者
WILLIAMS, EJ
DAVIDSON, EA
机构
[1] UNIV COLORADO,NOAA,COOPERAT INST RES ENVIRONM SCI,BOULDER,CO 80309
[2] WOODS HOLE RES CTR,WOODS HOLE,MA 02543
来源
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS | 1993年 / 27卷 / 14期
基金
美国安德鲁·梅隆基金会;
关键词
NO FLUX; ENCLOSURES; METHOD INTERCOMPARISON; CHEMILUMINESCENCE; SOILS;
D O I
10.1016/0960-1686(93)90040-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two chamber-based methods for measurement of emission of NO from soil have been compared. One method measured NO by conversion to NO2 with a CrO3 converter and NO2 detection by luminol chemiluminescence. The other technique detects NO directly via NO/ozone chemiluminescence. The techniques were tested with a glass manifold system by addition of NO and other trace gases into a flowing zero air ps stream; water vapor was also added to the carrier ps in some cases. A second set of tests involved the simultaneous determination of NO concentrations from a chamber placed over the soil. Finally, flux measurements were made independently from common plots and from different plots within the same field. The luminol system was unaffected by the presence of ammonia, methylamine, acetonitrile and nitrous oxide, but had a lower response to NO in the presence of water vapor. The decrease was 7% at a relative humidity of 50%, and about 3% at a relative humidity of 23%. The NO/ozone chemiluminescence system was not influenced by any of the species doped into the gas stream. The simultaneous chamber data also showed a decreased response from the luminol system that was consistent with the humidity effect observed in the manifold tests. The average of independently measured flux values from common plots agreed reasonably well. However, the overall site mean flux determined by the luminol system was 74% of that of the NO/ozone system due to a larger data set from the luminol system. This comparison demonstrates that flux spatial heterogeneity can overwhelm analytical uncertainties, and that large sample sizes are needed to accurately characterize field fluxes.
引用
收藏
页码:2107 / 2113
页数:7
相关论文
共 14 条
[11]   MEASUREMENT OF NITROGEN-OXIDE FLUXES FROM SOILS - INTERCOMPARISON OF ENCLOSURE AND GRADIENT MEASUREMENT TECHNIQUES [J].
PARRISH, DD ;
WILLIAMS, EJ ;
FAHEY, DW ;
LIU, SC ;
FEHSENFELD, FC .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1987, 92 (D2) :2165-2171
[12]   FIELD-MEASUREMENTS OF NO AND NO2 EMISSIONS FROM FERTILIZED AND UNFERTILIZED SOILS [J].
SLEMR, F ;
SEILER, W .
JOURNAL OF ATMOSPHERIC CHEMISTRY, 1984, 2 (01) :1-24
[13]   DETERMINATION OF NITROGEN-OXIDE EMISSIONS FROM SOILS - RESULTS FROM A GRASSLAND SITE IN COLORADO, UNITED-STATES [J].
WILLIAMS, EJ ;
PARRISH, DD ;
FEHSENFELD, FC .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1987, 92 (D2) :2173-2179
[14]   MEASUREMENT OF SOIL NOX EMISSIONS IN CENTRAL PENNSYLVANIA [J].
WILLIAMS, EJ ;
PARRISH, DD ;
BUHR, MP ;
FEHSENFELD, FC ;
FALL, R .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1988, 93 (D8) :9539-9546