COMPARISON OF INDIRECT AND DIRECT INSITU POLYMERASE CHAIN-REACTION IN CELL PREPARATIONS AND TISSUE-SECTIONS - DETECTION OF VIRAL-DNA, GENE REARRANGEMENTS AND CHROMOSOMAL TRANSLOCATIONS

被引:121
作者
LONG, AA
KOMMINOTH, P
LEE, E
WOLFE, HJ
机构
[1] UNIV ZURICH,DEPT PATHOL,DIV CELL & MOLEC PATHOL,CH-8091 ZURICH,SWITZERLAND
[2] TUFTS UNIV,NEW ENGLAND MED CTR HOSP,SCH MED,DEPT PATHOL & LAB MOLEC PATHOL,BOSTON,MA 02111
关键词
D O I
10.1007/BF00571876
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Different approaches to the in-situ polymerase chain reaction (in-situ PCR) were compared in the detection and in-situ localization of chromosomal translocations (t14; 18) immunoglobulin gene rearrangements and viral DNA (cytomegalovirus, hepatitis B-virus) in cell suspensions, cytospins and tissue sections. Single and multiple primer pairs were compared in the amplification step of indirect in-situ PCR and long genomic probes or internal oligonucleotide probes in the subsequent in-situ hybridization (ISH). For direct in-situ PCR, in which amplification products were directly labeled with digoxigenin-11-dUTP during PCR and detected immunohistochemically, only single primer pairs were used for amplification. In-situ PCR yielded best results in the cell suspensions and worked less efficiently in cytospins or tissue sections. Quantification of the results obtained in artificial cell mixtures yielded only an approximate correlation between the number of expected and observed positive cells. The specificity of the results was greater with indirect in-situ PCR than direct in-situ PCR, where false positive results were frequent. Successful indirect in-situ PCR in tissue sections required the use of multiple primer pairs for amplification and genomic probes for detection by ISH. False positive results in direct in-situ PCR were caused by primer-independent, but DNA polymerase- and cycling-dependent incorporation of digoxigenin-labeled nucleotides into cellular DNA, possibly related to DNA repair and/or internal priming. Non-specific results were most marked in tissue sections and were much less frequent in cell suspensions. In-situ PCR includes a number of different techniques, which are not equally applicable to different starting materials. Accurate interpretation of the results requires vigorous controls.
引用
收藏
页码:151 / 162
页数:12
相关论文
共 24 条
[1]   DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 PROVIRUS IN MONONUCLEAR-CELLS BY INSITU POLYMERASE CHAIN-REACTION [J].
BAGASRA, O ;
HAUPTMAN, SP ;
LISCHNER, HW ;
SACHS, M ;
POMERANTZ, RJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (21) :1385-1391
[2]  
BAGINSKI I, 1990, PCR PROTOCOLS GUIDE, P348
[3]  
BRIGATI D, 1983, VIROLOGY, V38, P470
[4]   INTRACELLULAR AMPLIFICATION OF PROVIRAL DNA IN TISSUE-SECTIONS USING THE POLYMERASE CHAIN-REACTION [J].
CHIU, KP ;
COHEN, SH ;
MORRIS, DW ;
JORDAN, GW .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1992, 40 (03) :333-341
[5]   DETECTION OF CYTOMEGALO-VIRUS IN URINE FROM NEWBORNS BY USING POLYMERASE CHAIN-REACTION DNA AMPLIFICATION [J].
DEMMLER, GJ ;
BUFFONE, GJ ;
SCHIMBOR, CM ;
MAY, RA .
JOURNAL OF INFECTIOUS DISEASES, 1988, 158 (06) :1177-1184
[6]  
DOMMINOTH P, 1992, DIAGN MOL PATHOL, V1, P85
[7]   RECENT ADVANCES IN THE POLYMERASE CHAIN-REACTION [J].
ERLICH, HA ;
GELFAND, D ;
SNINSKY, JJ .
SCIENCE, 1991, 252 (5013) :1643-1651
[8]   INSITU HYBRIDIZATION WITH DIGOXIGENIN-LABELED DNA PROBES FOR DETECTION OF VIRAL GENOMES [J].
FURUTA, Y ;
SHINOHARA, T ;
SANO, K ;
MEGURO, M ;
NAGASHIMA, K .
JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (10) :806-809
[9]   AMPLIFICATION AND DETECTION OF LENTIVIRAL DNA INSIDE CELLS [J].
HAASE, AT ;
RETZEL, EF ;
STASKUS, KA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (13) :4971-4975
[10]  
Komminoth P, 1992, Diagn Mol Pathol, V1, P142, DOI 10.1097/00019606-199206000-00008