ESTIMATION OF CHROMIUM-51 ETHYLENE DIAMINE TETRAACETIC ACID PLASMA-CLEARANCE - A COMPARATIVE-ASSESSMENT OF SIMPLIFIED TECHNIQUES

被引:56
作者
PICCIOTTO, G [1 ]
CACACE, G [1 ]
CESANA, P [1 ]
MOSSO, R [1 ]
ROPOLO, R [1 ]
DEFILIPPI, PG [1 ]
机构
[1] MOLINETTE MAURIZIANO HOSP, SERV FIS SANITARIA, I-10126 TURIN, ITALY
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1992年 / 19卷 / 01期
关键词
CHROMIUM-51 ETHYLENE DIAMINE TETRAACETIC ACID (CR-51-EDTA); GLOMERULAR FILTRATION RATE (GFR) TOTAL PLASMA CLEARANCE; KIDNEY FUNCTION;
D O I
10.1007/BF00178305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chromium-51 ethylene diamine tetra-acetic acid (Cr-51-EDTA) total plasma clearance was evaluated using a multi-sample method (i.c. 12 blood samples) as the reference compared with several simplified methods which necessitated only one or few blood samples. The following 5 methods were evaluated: terminal slope-intercept method with 3 blood samples, simplified method of Brochner-Mortensen and 3 single-sample methods (Constable, Christensen and Groth, Tauxc). Linear regression analysis was performed. Standard error of estimate, bias and imprecision of different methods were evaluated. For Cr-51-EDTA total plasma clearance greater than 30 ml.min-1, the results which most approximated the reference source were obtained by the Christensen and Groth method at a sampling time of 300 min (inaccuracy of 4.9%). For clearances between 10 and 30 ml.min-1, single-sample methods failed to give reliable results. Terminal slope-intercept and Brochner-Mortensen methods were better, with inaccuracies of 17.7% and 16.9%, respectively. Although sampling times at 180, 240 and 300 min are time-consuming for patients, Cr-51-EDTA total plasma clearance can be accurately calculated for values greater than 10 ml-min-1 using the Brochner-Mortensen method. In patients with clearance greater than 30 ml.min-1, single-sample techniques provide a good alternative to the multi-sample method; the choice of the method to be used depends on the degree of accuracy required.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 24 条
[1]  
BRAUNER L, 1981, CLIN PHYSIOL, V1, P175, DOI 10.1111/j.1475-097X.1981.tb00885.x
[2]   RENAL INULIN CLEARANCE VERSUS TOTAL PLASMA CLEARANCE OF 51CR-EDTA [J].
BROCHNER.J ;
GIESE, J ;
ROSSING, N .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1969, 23 (04) :301-&
[4]   COMPARISON BETWEEN TOTAL AND RENAL PLASMA CLEARANCE OF [EDTA-CR-51] [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (03) :247-249
[5]   SELECTION OF ROUTINE METHOD FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE IN ADULT PATIENTS [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :35-43
[6]   CURRENT STATUS ON ASSESSMENT AND MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
BROCHNERMORTENSEN, J .
CLINICAL PHYSIOLOGY, 1985, 5 (01) :1-17
[7]  
BROCHNERMORTENSEN J, 1978, DAN MED BULL, V25, P181
[8]  
CHANTLER C, 1969, CLIN SCI, V37, P169
[9]  
CHRISTENSEN AB, 1986, CLIN PHYSIOL, V6, P579
[10]   SINGLE SAMPLE ESTIMATES OF RENAL CLEARANCES [J].
CONSTABLE, AR ;
HUSSEIN, MM ;
ALBRECHT, MP ;
THOMPSON, FD ;
PHILALITHIS, PE ;
JOEKES, AM .
BRITISH JOURNAL OF UROLOGY, 1979, 51 (02) :84-87