SPATIOTEMPORAL CHARACTERISTICS OF PHYSIOLOGICAL GASTROESOPHAGEAL REFLUX

被引:65
作者
WEUSTEN, BLAM [1 ]
AKKERMANS, LMA [1 ]
VANBERGEHENEGOUWEN, GP [1 ]
SMOUT, AJPM [1 ]
机构
[1] UNIV UTRECHT HOSP,DEPT SURG,3508 GA UTRECHT,NETHERLANDS
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1994年 / 266卷 / 03期
关键词
INTRALUMINAL MULTICHANNEL PH MONITORING; DYNAMICS OF GASTROESOPHAGEAL REFLUX; AMBULATORY ESOPHAGEAL TESTING;
D O I
10.1152/ajpgi.1994.266.3.G357
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Spatiotemporal characteristics of physiological gastroesophageal reflux. Am. J. Physiol. 266 (Gastrointest. Liver physiol. 29): G357-G362, 1994. - Recent technological developments have made it possible to measure intraluminal pH simultaneously at multiple sites using one single small-caliber catheter. The aim of this study was to investigate the dynamics of physiological gastroesophageal reflux in eight ambulatory healthy volunteers (age 21-51 yr). Esophageal pH was recorded for 24 h at 3, 6, 9, 12, and 15 cm from the lower esophageal sphincter (LES), using an 8-Fr catheter containing five ion-sensitive field effect transistor (ISFET) pH transducers and a digital data logger. Signals were sampled at a rate of 4 Hz. Automated analysis included determination of the extent of the reflux (cm above LES) and calculation of the velocity of the advance of the pH front from the LES (ascending velocity), minimum pH reached, and duration of all individual reflux episodes at different segments in the esophagus. The reflux time and the number of reflux episodes/24 h showed a gradual decrease from the distal to the proximal sensor (mean +/- SE:4.4 +/- 0.8 to 0.9 +/- 0.2% and 46 +/- 7.6 to 11 +/- 1.9, respectively). Of all reflux episodes 23% did not reach the sensor at 6 cm above the LES, and only 25% reached the most proximal sensor. Characteristically, acid refluxed rapidly (velocity 0.4-2.4 cm/s) and was cleared in a stepwise fashion. Reflux episodes of long duration at the distal sensor reached high levels in the esophagus (P < 0.001). It was concluded that ambulatory multichannel esophageal pH monitoring using ISFET technology is a valuable tool for studies on the spatiotemporal characteristics of gastroesophageal reflux.
引用
收藏
页码:G357 / G362
页数:6
相关论文
共 29 条
  • [1] ARNDORFER RC, 1977, GASTROENTEROLOGY, V73, P23
  • [2] ON THE USE OF MONOCRYSTALLINE ANTIMONY PH ELECTRODES IN GASTRO-ESOPHAGEAL FUNCTIONAL-DISORDERS
    ASK, P
    EDWALL, G
    JOHANSSON, KE
    TIBBLING, L
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (03) : 383 - 389
  • [4] BOUSSE L, 1982, THESIS TH TWENTE
  • [5] Bruley Des Varannes Stanislas, 1992, Gastroenterologie Clinique et Biologique, V16, P406
  • [6] DENT J, 1976, GASTROENTEROLOGY, V71, P263
  • [7] THE ION SENSITIVE FIELD-EFFECT TRANSISTOR (ISFET) PH ELECTRODE - A NEW SENSOR FOR LONG-TERM AMBULATORY PH MONITORING
    DUROUX, P
    EMDE, C
    BAUERFEIND, P
    FRANCIS, C
    GRISEL, A
    THYBAUD, L
    ARMSTRONG, D
    DEPEURSINGE, C
    BLUM, AL
    [J]. GUT, 1991, 32 (03) : 240 - 245
  • [8] TECHNICAL ASPECTS OF INTRALUMINAL PH-METRY IN MAN - CURRENT STATUS AND RECOMMENDATIONS
    EMDE, C
    GARNER, A
    BLUM, AL
    [J]. GUT, 1987, 28 (09) : 1177 - 1188
  • [9] LONG-TERM AMBULATORY GASTRIC PH MONITORING - VALIDATION OF A NEW METHOD AND EFFECT OF H2-ANTAGONISTS
    FIMMEL, CJ
    ETIENNE, A
    CILLUFFO, T
    VONRITTER, C
    GASSER, T
    REY, JP
    CARADONNAMOSCATELLI, P
    SABBATINI, F
    PACE, F
    BUHLER, HW
    BAUERFEIND, P
    BLUM, AL
    [J]. GASTROENTEROLOGY, 1985, 88 (06) : 1842 - 1851
  • [10] EXTENDED 4-CHANNEL ESOPHAGEAL PH MONITORING - THE IMPORTANCE OF ACID REFLUX PATTERNS AT THE MIDDLE AND PROXIMAL LEVELS
    HAASE, GM
    ROSS, MN
    GANCECLEVELAND, B
    KOLACK, KE
    [J]. JOURNAL OF PEDIATRIC SURGERY, 1988, 23 (01) : 32 - 37