UREA SENSOR BASED ON AN AMMONIUM-ION-SENSITIVE FIELD-EFFECT TRANSISTOR

被引:24
作者
MIYAHARA, Y
TSUKADA, K
MIYAGI, H
SIMON, W
机构
[1] Central Research Laboratory, Hitachi Ltd., Kokubunji, Tokyo, 185, 1-280, Higashikoigakubo
[2] Department of Organic Chemistry, Swiss Federal Institute of Technology, CH-8092 Zurich
关键词
D O I
10.1016/0925-4005(91)80019-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A urea sensor based on an ammonium-ion-sensitive field-effect transistor has been realized in combination with an immobilized urease membrane. The effect of buffer concentrations on the response characteristics of the sensor is investigated. The lower detection limit, as given by the calibration curve, is strongly affected by the concentrations of potassium and sodium ions, while its slope in the appropriate buffer solution is independent of the buffer concentration in a limited urea concentration range. Although the slope in physiological saline solution is only 18 mV/dec, the dynamic range of the sensor covers the physiological range of urea in blood. The small slope and the narrow dynamic range are found to be due to poor selectivity of the ammonium-ion-selective membrane over sodium and potassium ions. It is, therefore, possible to improve the sensor response characteristics by improving the selectivity of the ammonium-ion-selective membrane.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 25 条
[1]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[2]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .3. PENICILLIN-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1924-1925
[3]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .2. GLUCOSE-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
PETELENZ, D ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1920-1923
[4]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .1. THEORY [J].
CARAS, SD ;
JANATA, J ;
SAUPE, D ;
SCHMITT, K .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1917-1920
[5]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - ANALYTICAL SOLUTION FOR THE RESPONSE IN THE PRESENCE OF PH BUFFER [J].
EDDOWES, MJ .
SENSORS AND ACTUATORS, 1987, 11 (03) :265-274
[6]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - EXPERIMENTAL-STUDY OF A GLUCOSE OXIDASE MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTOR IN BUFFERED AND UNBUFFERED AQUEOUS-SOLUTION [J].
EDDOWES, MJ ;
PEDLEY, DG ;
WEBB, BC .
SENSORS AND ACTUATORS, 1985, 7 (04) :233-244
[7]  
GUILBAUL.GG, 1970, J AM CHEM SOC, V92, P2533
[8]   ELECTRODE FOR DETERMINATION OF AMINO ACIDS [J].
GUILBAULT, GG ;
HRABANKOVA, E .
ANALYTICAL CHEMISTRY, 1970, 42 (14) :1779-+
[9]   ENZYME ELECTRODES BASED ON USE OF CARBON-DIOXIDE SENSOR - UREA AND L-TYROSINE ELECTRODES [J].
GUILBAULT, GG ;
SHU, FR .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2161-+
[10]   A UREA-SPECIFIC ENZYME ELECTRODE [J].
GUILBAULT, GG ;
MONTALVO, JG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (08) :2164-+