EVALUATION OF THE PARTICLE-BEAM INTERFACE FOR PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY MASS-SPECTROMETRY WITH PURE AND MODIFIED CO2

被引:8
作者
JEDRZEJEWSKI, PT [1 ]
TAYLOR, LT [1 ]
机构
[1] VIRGINIA POLYTECH INST & STATE UNIV,DEPT CHEM,BLACKSBURG,VA 24061
关键词
D O I
10.1016/0021-9673(94)80164-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The particle beam interface was evaluated for microbore packed-column supercritical fluid chromatography-mass spectrometry coupling. The experiments were conducted with mobile phase of pure CO2 and methanol-modified CO2 under flow injection and chromatographic conditions. The effects of various operational parameters were characterized. The electron impact limits of detection (LODs) of the system for single ion monitoring and scan modes were determined to be 5 and 40 ng for caffeine, respectively. These LODs are 2.5 to 25 times better than previous reported estimates. Sensitivity was found to be highly dependent on the modifier percentage with 4% methanol-modified CO2 yielding optimal results. Separations of phenylurea pesticides and steroids are shown as demonstrations of system utility. Background subtracted electron impact spectra were artifact-free and comparable with on-line library spectra.
引用
收藏
页码:365 / 376
页数:12
相关论文
共 30 条
[21]  
MARTIN LE, 1982, J CHROMATOGR, V251, P223
[22]  
MCLAUGHLIN L, 1989, 6TH MONT S LC MS COR
[23]  
RAMSEY ED, 1989, J CHROMATOGR, V464, P353, DOI 10.1016/S0021-9673(00)94253-5
[24]   DIRECT COUPLING OF A DENSE (SUPERCRITICAL) GAS-CHROMATOGRAPH TO A MASS-SPECTROMETER USING A SUPERSONIC MOLECULAR-BEAM INTERFACE [J].
RANDALL, LG ;
WAHRHAFTIG, AL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (09) :1283-1295
[25]   CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY WITH ELECTRON-IMPACT IONIZATION [J].
SMITH, RD ;
UDSETH, HR ;
KALINOSKI, HT .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2971-2973
[26]   MONODISPERSE AEROSOL GENERATION INTERFACE FOR COMBINING LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROSCOPY [J].
WILLOUGHBY, RC ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2626-2631
[27]   PERFORMANCE OF AN IMPROVED MONODISPERSE AEROSOL GENERATION INTERFACE FOR LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
WINKLER, PC ;
PERKINS, DD ;
WILLIAMS, WK ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :489-493
[28]  
WINKLER PC, 1986, THESIS GEORGIA I TEC
[29]   CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY [J].
WRIGHT, BW ;
KALINOSKI, HT ;
UDSETH, HR ;
SMITH, RD .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (03) :145-153
[30]  
YERGEY AL, 1990, LIQUID CHROMATOGRAPH, P19