INTERNAL FORCES AND MOMENTS IN TRANSPEDICULAR SPINE INSTRUMENTATION - THE EFFECT OF PEDICLE SCREW ANGLE AND TRANSFIXATION - THE 4R-4BAR LINKAGE CONCEPT

被引:52
作者
CARSON, WL
DUFFIELD, RC
ARENDT, M
RIDGELY, BJ
GAINES, RW
机构
[1] Mechanical and Aerospace Engineering Department, Columbia
[2] Division of Orthopaedic Surgery, University of Missouri-Columbia, Columbia, MO
关键词
Biomechanics; Internal loads; Linkage instability; Pedicle angle; Pedicle screw; Spine implant; Structure; Transfixation;
D O I
10.1097/00007632-199009000-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The three-dimensional components of force and moment within the plates and screws of a bilevel transpedicular spine implant construct subjected to different physiolog-ical loads were determined by experimental and finite element methods. The effect of pedicle screw angle and transfixation were studied. Untransfixed 0° pedicle-to- pedicle (P-P) angle constructs with limited screw-bone torsional resistance are unstable 4R-4bar linkages. They will not resist lateral load or (when not in a rectangular position) axial load until the spinal column load shares. Untransfixed constructs with (0° < P-P angle < 60°) are structures. However, as P-P angle approaches 0°, the structure becomes more flexible (unstable) and some internal force and moment components exponentially increase (starting at approximately a 30° P-P angle). Transfixation eliminated the linkage instability and asso-ciated exponential increase in internal loads. These ob-servations apply to all bilevel systems that allow no relative joint motion between pedicle screw and longitudinal member. If relative motion does exist, other types of linkage instability can occur. © Lippincott-Raven Publishers.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 26 条
[21]  
Roy-Camille R., Saillant G., Mazel C., Internal fixation of the lumbar spine with pedicle screw plating, Clin Orthop, 203, pp. 7-17, (1986)
[22]  
Shultz A.B., Ersson G., Analysis of loads on the lumbar spine, Spine, 6, pp. 76-82, (1981)
[23]  
Schultz A.B., Ersson G., Haderspeck K., Ortengren R., NordinM, Bjork R: Analysis and measurement of lumbar trunk loads in tasks involving bends. And twists, J Biomech, 15, pp. 669-675, (1982)
[24]  
Steffee A.D., Sitkowski D.J., Posterior lumbar interbody fusion and plates, Clin Orthop, 227, pp. 99-102, (1988)
[25]  
TSRH Spinal Implant System
[26]  
Yettram A.L., Jackman M.J., Equilibrium analysis for the forces in the human spinal column and its musculature, Spine, 5, pp. 402-422, (1980)