RETROSPECTIVE CORRECTION OF INTENSITY INHOMOGENEITIES IN MRI

被引:127
作者
MEYER, CR
BLAND, PH
PIPE, J
机构
[1] Univ of Michigan, Ann Arbor
基金
美国国家卫生研究院;
关键词
D O I
10.1109/42.370400
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Medical imaging data sets are often corrupted by multiplicative inhomogeneities, often referred to as nonuniformities or intensity variations, that hamper the use of quantitative analyses, We describe an automatic technique that not only improves the worst situations, such as those encountered with magnetic resonance imaging (MRI) surface coils, but also corrects typical inhomogeneities encountered in routine volume data sets, such as MRI head scans, without generating additional artifact, Because the technique uses only the patient data set, the technique can be applied retrospectively to all data sets, and corrects both patient independent effects, such as rf coil design, and patient dependent effects, such as attenuation of overlying tissue experienced both in high field MRI and X-ray computed tomography (CT), We show results for several MRI imaging situations including thorax, head, and breast, Following such corrections, region of interest analyses, volume histograms, and thresholding techniques are more meaningful, The value of such correction algorithms may increase dramatically with increased use of high field strength magnets and associated patient dependent rf attenuation in overlying tissues.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 18 条
[1]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[2]   CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING [J].
BREY, WW ;
NARAYANA, PA .
MEDICAL PHYSICS, 1988, 15 (02) :241-245
[3]  
CARSWELL H, 1993, MR NEWSMAG MAGNET RE, V3, P7
[4]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781
[5]   REDUCTION OF RF PENETRATION EFFECTS IN HIGH-FIELD IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :287-301
[6]  
HASELGROVE J, 1986, Magnetic Resonance Imaging, V4, P469, DOI 10.1016/0730-725X(86)90024-X
[7]   ANALYSIS OF BRAIN AND CEREBROSPINAL-FLUID VOLUMES WITH MR IMAGING .1. METHODS, RELIABILITY, AND VALIDATION [J].
KOHN, MI ;
TANNA, NK ;
HERMAN, GT ;
RESNICK, SM ;
MOZLEY, PD ;
GUR, RE ;
ALAVI, A ;
ZIMMERMAN, RA ;
GUR, RC .
RADIOLOGY, 1991, 178 (01) :115-122
[8]   A PARALLEL TECHNIQUE FOR SIGNAL-LEVEL PERCEPTUAL ORGANIZATION [J].
LIOU, SP ;
CHIU, AH ;
JAIN, RC .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1991, 13 (04) :317-325
[9]   AN APPROACH TO 3-DIMENSIONAL IMAGE SEGMENTATION [J].
LIOU, SP ;
JAIN, RC .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (03) :237-252
[10]  
Listerud J, 1989, J Digit Imaging, V2, P2