TECHNIQUES FOR HIGH-RESOLUTION ECHO-PLANAR MR IMAGING OF THE PANCREAS

被引:24
作者
REIMER, P
SAINI, S
HAHN, PF
MUELLER, PR
BRADY, TJ
COHEN, MS
机构
[1] MASSACHUSETTS GEN HOSP, CTR MGH NMR, 32 FRUIT ST, BOSTON, MA 02114 USA
[2] MASSACHUSETTS GEN HOSP, DEPT RADIOL, DIV GASTROINTESTINAL RADIOL, BOSTON, MA 02114 USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA 02114 USA
关键词
MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; ECHO PLANAR; PULSE SEQUENCES; TISSUE CHARACTERIZATION; PANCREAS; MR; NEOPLASMS; PANCREATITIS;
D O I
10.1148/radiology.182.1.1727278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent technical advances in echo-planar magnetic resonance (MR) imaging prompted an investigation of these new techniques in pancreatic MR imaging and evaluation of bowel lumen enhancement with an aqueous bowel contrast agent. In 42 subjects (36 healthy, six with pancreatic disease), various T1-weighted inversion-recovery and T2-weighted spin-echo fat-suppressed pulse sequences were assessed with an echo-planar technique implemented with a modified clinical MR imager. Single-excitation imaging (echo time, 26 msec) provided a higher (P < .05) signal-to-noise ratio than did conventional spin-echo and all other echo-planar techniques. In 13 (72%) of 18 healthy subjects who did not undergo administration of the contrast agent, the entire pancreas was distinguished from adjoining bowel. In all 18 subjects who underwent contrast-enhanced imaging, a significantly greater (P < .05) intraluminal signal intensity was apparent with all echo-planar pulse sequences and the entire pancreas was identified. In six patients with pancreatic disease, lesions could be identified by their difference in signal intensity.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 22 条
  • [11] RZEDZIAN R, 1987, SOC MAGN RESON MED, P51
  • [12] INSTANT IMAGES OF THE HUMAN-HEART USING A NEW, WHOLE-BODY MR IMAGING-SYSTEM
    RZEDZIAN, RR
    PYKETT, IL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) : 245 - 250
  • [13] RZEDZIAN RR, 1968, Patent No. 4767991
  • [14] 40-MILLISECOND MR IMAGING OF THE ABDOMEN AT 2.0 T
    SAINI, S
    STARK, DD
    RZEDZIAN, RR
    PYKETT, IL
    RUMMENY, E
    HAHN, PF
    WITTENBERG, J
    FERRUCCI, JT
    [J]. RADIOLOGY, 1989, 173 (01) : 111 - 116
  • [15] ADVANCES IN CONTRAST-ENHANCED MR-IMAGING
    SAINI, S
    MODIC, MT
    HAMM, B
    HAHN, PF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (02) : 235 - 254
  • [16] WHOLE-BODY ECHO-PLANAR MR IMAGING AT 0.5 T
    STEHLING, MJ
    HOWSEMAN, AM
    ORDIDGE, RJ
    CHAPMAN, B
    TURNER, R
    COXON, R
    GLOVER, P
    MANSFIELD, P
    COUPLAND, RE
    [J]. RADIOLOGY, 1989, 170 (01) : 257 - 263
  • [17] GASTROINTESTINAL-TRACT - DYNAMIC MR STUDIES WITH ECHO-PLANAR IMAGING
    STEHLING, MK
    EVANS, DF
    LAMONT, G
    ORDIDGE, RJ
    HOWSEMAN, AM
    CHAPMAN, B
    COXON, R
    MANSFIELD, P
    HARDCASTLE, JD
    COUPLAND, RE
    [J]. RADIOLOGY, 1989, 171 (01) : 41 - 46
  • [18] IMAGING OF PANCREATIC NEOPLASMS - COMPARISON OF MR AND CT
    STEINER, E
    STARK, DD
    HAHN, PF
    SAINI, S
    SIMEONE, JF
    MUELLER, PR
    WITTENBERG, J
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) : 487 - 491
  • [19] MR IMAGING IN THE DIAGNOSIS OF PANCREATIC DISEASE
    TSCHOLAKOFF, D
    HRICAK, H
    THOENI, R
    WINKLER, ML
    MARGULIS, AR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (04) : 703 - 709
  • [20] SINGLE BREATH-HOLDING SCANS OF THE ABDOMEN USING FISP AND FLASH AT 1.5-T
    UNGER, EC
    COHEN, MS
    GATENBY, RA
    CLAIR, MR
    BROWN, TR
    NELSON, SJ
    MCGLONE, JS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (04) : 575 - 583