In this paper it will be shown that real high-performance liquid chromatographic-ultraviolet (HPLC-UV) data do not perfectly obey the exact linear model assumed in most multivariate techniques. These small model errors may have an influence on the performance of multivariate techniques, especially on the principal component analysis step in which a reduced multivariate space is defined. In order to obtain a more realistic picture of the performance of multivariate techniques in practice, simulations of peak clusters are proposed that make use of real peak systems of pure analytes. It wilt be shown that these realistically simulated data contain the same small model errors that can be observed for real HPLC-UV data.
引用
收藏
页码:257 / 268
页数:12
相关论文
共 24 条
[11]   DETERMINATION OF NUMBER OF FACTORS AND EXPERIMENTAL ERROR IN A DATA MATRIX [J].
MALINOWSKI, ER .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :612-617
[12]   THEORY OF ERROR APPLIED TO PURE TEST VECTORS IN TARGET FACTOR-ANALYSIS [J].
MALINOWSKI, ER .
ANALYTICA CHIMICA ACTA-COMPUTER TECHNIQUES AND OPTIMIZATION, 1981, 5 (01) :99-101
[13]  
Ohman J., 1990, J CHEMOMETR, V4, P135
[14]   RANK ESTIMATION OF EXCITATION EMISSION MATRICES USING FREQUENCY-ANALYSIS OF EIGENVECTORS [J].
ROSSI, TM ;
WARNER, IM .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :810-815
[15]   GENERALIZED RANK ANNIHILATION FACTOR-ANALYSIS [J].
SANCHEZ, E ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :496-499
[16]   RELIABILITY OF ITERATIVE TARGET TRANSFORMATION FACTOR-ANALYSIS WHEN USING MULTIWAVELENGTH DETECTION FOR PEAK TRACKING IN LIQUID-CHROMATOGRAPHIC SEPARATIONS [J].
STRASTERS, JK ;
BILLIET, HAH ;
DEGALAN, L ;
VANDEGINSTE, BGM ;
KATEMAN, G .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2745-2751
[17]  
STRASTERS JK, 1988, THESIS DELFT U
[18]   CANONICAL CORRELATION TECHNIQUE FOR RANK ESTIMATION OF EXCITATION-EMISSION MATRICES [J].
TU, XM ;
BURDICK, DS ;
MILLICAN, DW ;
MCGOWN, LB .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :2219-2224
[19]   MULTICOMPONENT SELF-MODELING CURVE RESOLUTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY ITERATIVE TARGET TRANSFORMATION ANALYSIS [J].
VANDEGINSTE, BGM ;
DERKS, W ;
KATEMAN, G .
ANALYTICA CHIMICA ACTA, 1985, 173 (JUL) :253-264
[20]  
VANDEGINSTE BGM, 1987, J CHEMOMETR, V1, P57