Some types of reused dental equipment, especially handpieces and their attachments for drilling and cleaning teeth, might be responsible for cross-contamination if patient material were to lodge temporarily in difficult-to-disinfect internal mechanisms. This possibility is worrisome with respect to transmission of hepatitis B and human immunodeficiency viruses (HBV, HIV). Previous cross-contamination studies have relied on laboratory experiments with bacteria or dye tracers. To assess possible risks more thoroughly, we tested 30 new prophylaxis angles and 12 new high-speed handpieces to see whether they would take up and expel contaminants in laboratory and clinical trials. In treatments of three patients, including two infected with HIV, human-specific DNA (beta-globin, HLA DQalpha) and HIV proviral DNA were detected inside or coming back from the devices. Similarly, when handpieces were operated in contact with blood pooled from HBV-infected patients, HBV DNA was detected in samples taken from inside the equipment and from their attached air/water hoses. When we used bacteriophage phiX174 as a model virus in laboratory tests, many infective viral particles were recovered from internal mechanisms of handpieces, their connecting air/water hoses, and from water spray expelled when the equipment was reused. We recommend that reused high-speed, air-driven handpieces and prophylaxis angles should be cleaned and heat-treated between patients. Further studies are needed to determine ways of eliminating the risks associated with exhaust hoses and air/water input lines.
引用
收藏
页码:1252 / 1254
页数:3
相关论文
共 11 条
[1]   STUDIES ON DENTAL AEROBIOLOGY .4. BACTERIAL CONTAMINATION OF WATER DELIVERED BY DENTAL UNITS [J].
ABEL, LC ;
MILLER, RL ;
MICIK, RE ;
RYGE, G .
JOURNAL OF DENTAL RESEARCH, 1971, 50 (06) :1567-&
[2]   SIMPLE, SENSITIVE, AND SPECIFIC DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 IN CLINICAL SPECIMENS BY POLYMERASE CHAIN-REACTION WITH NESTED PRIMERS [J].
ALBERT, J ;
FENYO, EM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (07) :1560-1564
[3]   CONTAMINATION OF DENTAL UNIT COOLING WATER WITH ORAL MICROORGANISMS AND ITS PREVENTION [J].
BAGGA, BSR ;
MURPHY, RA ;
ANDERSON, AW ;
PUNWANI, I .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1984, 109 (05) :712-716
[4]   INFECTION CONTROL - SOME SIGNIFICANT LOOPHOLES [J].
CHRISTENSEN, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1991, 122 (09) :99-100
[5]  
Erlich H. A., 1990, PCR PROTOCOLS, P261
[6]   CROSS-INFECTION RISKS ASSOCIATED WITH CURRENT PROCEDURES FOR USING HIGH-SPEED DENTAL HANDPIECES [J].
LEWIS, DL ;
BOE, RK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (02) :401-406
[7]   THE SIGNIFICANCE OF THE BACTERIAL-CONTAMINATION OF DENTAL UNIT WATER-SYSTEMS [J].
MARTIN, MV .
BRITISH DENTAL JOURNAL, 1987, 163 (05) :152-154
[8]   LASER EVALUATION OF HANDPIECE CONTAMINATION [J].
PELZNER, RB ;
KEMPLER, D ;
STARK, MM ;
BARKIN, PR ;
GRAHAM, DA .
JOURNAL OF DENTAL RESEARCH, 1977, 56 (12) :1629-1634
[9]   ENZYMATIC AMPLIFICATION OF BETA-GLOBIN GENOMIC SEQUENCES AND RESTRICTION SITE ANALYSIS FOR DIAGNOSIS OF SICKLE-CELL ANEMIA [J].
SAIKI, RK ;
SCHARF, S ;
FALOONA, F ;
MULLIS, KB ;
HORN, GT ;
ERLICH, HA ;
ARNHEIM, N .
SCIENCE, 1985, 230 (4732) :1350-1354
[10]   REDUCTION OF MICROBES IN HANDPIECES BY FLUSHING BEFORE USE [J].
SCHEID, RC ;
KIM, CK ;
BRIGHT, JS ;
WHITELY, MS ;
ROSEN, S .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1982, 105 (04) :658-660