REVIEW OF THE EXPONENTIALLY MODIFIED GAUSSIAN (EMG) FUNCTION SINCE 1983

被引:115
作者
JEANSONNE, MS [1 ]
FOLEY, JP [1 ]
机构
[1] LOUISIANA STATE UNIV, DEPT CHEM, BATON ROUGE, LA 70803 USA
关键词
D O I
10.1093/chromsci/29.6.258
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Growing acceptance of the exponentially modified Gaussian (EMG) function as a good model for real chromatographic peaks has prompted a review of its use since 1983. This review covers the following areas: (1) equations derived from the EMG model, (2) studies of inherent errors in the quantitation of chromatographic peaks via use of the EMG model, (3) chromatographic applications since 1983, and (4) applications to flow injection analysis. The goals of this review are to provide a valuable resource to researchers already employing the EMG model, while also providing a foundation for prospective first time users.
引用
收藏
页码:258 / 266
页数:9
相关论文
共 127 条
[81]   DIRECT MEASUREMENT OF LIQUID-CHROMATOGRAPHIC SORPTION DESORPTION-KINETICS AND THE KINETIC CONTRIBUTION TO BAND BROADENING [J].
MARSHALL, DB ;
BURNS, JW ;
CONNOLLY, DE .
JOURNAL OF CHROMATOGRAPHY, 1986, 360 (01) :13-24
[82]  
MARSHALL DB, 1986, J CHROMATOGR, V361, P71
[83]   SYNTHESIS OF LC REVERSED PHASES OF HIGHER EFFICIENCY BY INITIAL PARTIAL DEACTIVATION OF THE SILICA SURFACE [J].
MARSHALL, DB ;
STUTLER, KA ;
LOCHMULLER, CH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (06) :217-220
[84]   DETERMINATION OF IBUPROFEN IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MINKLER, PE ;
HOPPEL, CL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (02) :388-394
[85]   RAPID HIGH-PERFOMANCE LIQUID-CHROMATOGRAPHY OF 3-METHYLHISTIDINE IN HUMAN-URINE [J].
MINKLER, PE ;
INGALLS, ST ;
GRIFFIN, RL ;
HOPPEL, CL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 :33-42
[86]   IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF 6-N,N,N-TRIMETHYLLYSINE IN PLASMA AND URINE - BIOMEDICAL APPLICATION OF CHROMATOGRAPHIC FIGURES OF MERIT AND AMINE MOBILE PHASE MODIFIERS [J].
MINKLER, PE ;
ERDOS, EA ;
INGALLS, ST ;
GRIFFIN, RL ;
HOPPEL, CL .
JOURNAL OF CHROMATOGRAPHY, 1986, 380 (02) :285-299
[87]   SELECTIVITY AND EFFICIENCY MEASUREMENTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING MICELLAR HEXADECYLTRIMETHYLAMMONIUM BROMIDE IN THE MOBILE PHASE [J].
MULLINS, FGP ;
KIRKBRIGHT, GF .
ANALYST, 1986, 111 (11) :1273-1279
[88]  
MULLINS FGP, 1987, ACS SYM SER, V342, P115
[89]   EXPONENTIALLY MODIFIED GAUSSIAN FUNCTIONS - A GOOD MODEL FOR CHROMATOGRAPHIC PEAKS IN ISOCRATIC HPLC [J].
NAISH, PJ ;
HARTWELL, S .
CHROMATOGRAPHIA, 1988, 26 :285-296
[90]   OPEN-TUBULAR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY USING DIRECT LIQUID INTRODUCTION [J].
NIESSEN, WMA ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01) :37-46