DUAL-ENERGY X-RAY ABSORPTIOMETRY OF IMPLANTED FEMORA AFTER CEMENTED AND PRESS-FIT TOTAL HIP-ARTHROPLASTY IN A CANINE MODEL

被引:23
作者
MARKEL, MD [1 ]
GOTTSAUNERWOLF, F [1 ]
BOGDANSKE, JJ [1 ]
WAHNER, HW [1 ]
CHAO, EYS [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT ORTHOPED, BIOMECH LAB, ROCHESTER, MN 55905 USA
关键词
D O I
10.1002/jor.1100110319
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of a press-fit and cemented titanium alloy endoprosthesis on the measurement of bone mineral density (BMD) of the proximal femur in a canine model with dual energy x-ray absorptiometry (DXA) was determined. Seven regions of interest, corresponding to zones 1-7 according to Gruen et al., were measured. Eight unpaired femora were scanned with DXA before implantation (five separate scans per femur), after press-fitting with a titanium alloy femoral component (five separate scans per femur); and after cementing with the same component (five separate scans per femur). When the titanium alloy endoprosthesis was press-fit, the BMD of five of seven regions of the proximal femur increased significantly (range, 2.7-23.1%; mean, 11.2%), although the mean precision error of this measurement was not altered (before implantation, 1.1%; after press-fit 1.8%). Cementing of the implant caused a variable effect on BMD, resulting in a decrease in distal regions where cortical bone was relatively thin compared with the cement mantle (regions 3, 4, and 5) and in an increase in the other regions. Cementing of the implant significantly increased the mean precision error of measurement to 7.2% (range, 1.1-12.6%).
引用
收藏
页码:452 / 456
页数:5
相关论文
共 16 条
[1]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[2]   RADIOGRAPHIC CHANGES IN BONE DIMENSIONS IN ASYMPTOMATIC CEMENTED TOTAL HIP ARTHROPLASTIES - RESULTS OF 9-YEAR TO 13-YEAR FOLLOW-UP [J].
COMADOLL, JL ;
SHERMAN, RE ;
GUSTILO, RB ;
BECHTOLD, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :433-438
[3]  
Gruen TA, 1979, CLIN ORTHOP RELAT R, V141, P17
[4]   FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION [J].
HARRIS, WH ;
MCCARTHY, JC ;
ONEILL, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1063-1067
[5]   LOOSENING OF THE FEMORAL COMPONENT AFTER USE OF THE MEDULLARY-PLUG CEMENTING TECHNIQUE - FOLLOW-UP NOTE WITH A MINIMUM 5-YEAR FOLLOW-UP [J].
HARRIS, WH ;
MCGANN, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1064-1066
[6]  
KIRATLI BJ, 1991, J BONE MINER RES S1, V6, pS110
[7]  
KIRATLI BJ, 1992, T ORTHOP RES SOC, V17, P238
[8]  
Lilley J, 1991, Osteoporos Int, V1, P141, DOI 10.1007/BF01625443
[9]  
MARKEL MD, 1992, AM J VET RES, V53, P2105
[10]   THE POWER OF A STATISTICAL TEST - WHAT DOES INSIGNIFICANCE MEAN [J].
MARKEL, MD .