SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS

被引:48
作者
FLOYD, CE [1 ]
BAKER, JA [1 ]
CHOTAS, HG [1 ]
DELONG, DM [1 ]
RAVIN, CE [1 ]
机构
[1] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27710
关键词
D O I
10.2214/ajr.165.6.7484562
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. A new digital thoracic radiography system (Thoravision; Philips Medical Systems, Hamburg, Germany), which uses selenium as a detector material, was evaluated for observer preference. The system has been shown to have higher detection efficiency than conventional film-screen systems and thus could provide an image with reduced noise. The hypothesis tested in this study was that the selenium-based digital system would provide an image appearance for conventional thoracic imaging that would be equal or superior to that provided by a conventional film-screen system. MATERIALS AND METHODS. Fifty-three patient volunteers were imaged at 120 kV with both the selenium-based system and a thoracic film-screen combination system (InSight HC; Kodak, Rochester, NY). Posteroanterior and lateral images were acquired with both systems, for a total of 212 images. Both imaging systems included a stationary 12:1 antiscatter grid. Exposures were the same for both imaging systems, and the digital images were printed to film. Images for the same patient were compared by six observers-three specialized chest radiologists and three general radiologists. Images included both normal chest radiographs and radiographs with abnormal findings. Each pair of images was ranked on a scale from 1 to 5 for preference of technique, with a score of 3 indicating no preference. Eleven anatomic features were evaluated in the posteroanterior views, and six features were evaluated in the lateral views. Statistical significance of preference was evaluated with Student's t test. RESULTS. The chest radiologists had a statistically significant preference for the serenium-based system for all 17 features (p < .001). The general radiologists had a statistically significant preference for the selenium-based system for visualization of 10 of the 17 features (p < .05). Neither group had a statistically significant preference for the conventional images in any category. CONCLUSION. The selenium-based system provided an image appearance that was significantly preferred by all radiologists, more strongly by those specializing in chest radiography. This study demonstrates that a digital thoracic imaging system can routinely produce images that are perceived as equal or superior to conventional images.
引用
收藏
页码:1353 / 1358
页数:6
相关论文
共 4 条
  • [1] BUNCH PC, 1992, P SOC PHOTO-OPT INS, V1653, P46, DOI 10.1117/12.59484
  • [2] TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR
    CHOTAS, HG
    FLOYD, CE
    RAVIN, CE
    [J]. RADIOLOGY, 1995, 195 (01) : 264 - 270
  • [3] FLOYD CE, 1994, P SOC PHOTO-OPT INS, V2163, P110
  • [4] IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR
    NEITZEL, U
    MAACK, I
    GUNTHERKOHFAHL, S
    [J]. MEDICAL PHYSICS, 1994, 21 (04) : 509 - 516