GAS-CHROMATOGRAPHY ATOMIC-EMISSION DETECTION (GC-AED) SET-UP FOR BIO-MONITORING OF PCBS AND METHYLSULFONYL-PCBS

被引:14
作者
JANAK, K
GRIMVALL, E
OSTMAN, C
COLMSJO, A
ATHANASIADOU, M
BERGMAN, A
机构
[1] NATL INST OCCUPAT HLTH,DEPT ANALYT CHEM,S-17184 SOLNA,SWEDEN
[2] UNIV STOCKHOLM,WALLENBERG LAB,S-10691 STOCKHOLM,SWEDEN
关键词
GC-AED; OPTIMIZATION OF RESPONSE; PCBS; METHYLSULFONYL-PCBS; BIOLOGICAL SAMPLES;
D O I
10.1002/mcs.1220060612
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas chromatography-atomic emission detection (GC-AED) has been evaluated in order to determine the optimal conditions for chlorine and sulfur response of chlorinated biphenyls (CBs) and methylsulfonyl metabolites of CBs (MeSO(2)-CBs). The influence of the shape of the capillary column end facing the plasma, make-up gas flow, additional transfer line make-up gas flow and reagent gas flows on the detector response has been studied. Using an additional make-up gas flow applied through a transfer line capillary having a decreased outlet diameter yielded an increased detector response with minimum detectable levels for sulfur and chlorine of 1.7 and 20 pg, respectively. Further, a substantial decrease in peak tailing was achieved. The applicability of the method for analysis of biological materials is demonstrated by the determination of the main CB congeners present in human blood and of MeS0(2)-CBs in seal
引用
收藏
页码:605 / 616
页数:12
相关论文
共 27 条
[11]  
COOKE M, 1993, J HIGH RES CHROMATOG, V16, P660
[12]   COMPARISON OF COMMERCIALLY AVAILABLE ATOMIC EMISSION AND CHEMILUMINESCENCE DETECTORS FOR SULFUR-SELECTIVE GAS-CHROMATOGRAPHIC DETECTION [J].
ECKERTTILOTTA, SE ;
HAWTHORNE, SB ;
MILLER, DJ .
JOURNAL OF CHROMATOGRAPHY, 1992, 591 (1-2) :313-323
[13]   A LAMINAR-FLOW MICROWAVE PLASMA DETECTOR FOR GAS-CHROMATOGRAPHY [J].
FIELDEN, PR ;
JIANG, M ;
SNOOK, RD .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1444-1449
[14]   USE OF A TANGENTIAL-FLOW TORCH WITH A MICROWAVE-INDUCED PLASMA EMISSION DETECTOR FOR GAS-CHROMATOGRAPHY [J].
GOODE, SR ;
CHAMBERS, B ;
BUDDIN, NP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 :329-333
[15]   SYNTHESIS AND CHARACTERIZATION OF TISSUE-RETAINABLE METHYLSULFONYL POLYCHLORINATED BIPHENYL ISOMERS [J].
HARAGUCHI, K ;
KUROKI, H ;
MASUDA, Y .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1987, 35 (02) :178-182
[16]   NEGATIVE-ION CHEMICAL-IONIZATION MASS-SPECTROMETRY IN THE ANALYSIS OF POLYCHLORINATED BIPHENYL METHYL SULFONES [J].
HARAGUCHI, K ;
BERGMAN, A ;
JAKOBSSON, E ;
MASUDA, Y .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :441-449
[17]  
HARAGUCHI K, 1992, AMBIO, V21, P546
[18]  
JANAK K, UNPUB J HIGH RESOLUT
[19]  
JANAK K, 1994, J HIGH RES CHROMATOG, V17, P135
[20]   ENVIRONMENTAL MONITORING OF POLYCHLORINATED-BIPHENYLS USING PINE NEEDLES AS PASSIVE SAMPLERS [J].
KYLIN, H ;
GRIMVALL, E ;
OSTMAN, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (07) :1320-1324