Guidelines for the prevention of nosocomial pneumonia specify that only sterile fluids should be used for aerosol therapy; however, this recommendation may not be uniformly followed. Thirteen patients with nosocomial pneumonia due to Legionella pneumophila serogroup 3 (Lp3) were identified at a community hospital in the period from 1984 through 1988; 12 patients (92%) had chronic obstructive pulmonary disease; and 9 patients (69%) died. An epidemiologic investigation suggested that the use of nebulizers to deliver medication was associated with acquiring legionnaires' disease. The hospital potable water system was contaminated with Lp3, and a survey indicated that tap water was commonly used to wash medication nebulizers. Lp3 in respirable-size droplets was isolated from aerosols generated by a nebulizer containing Lp3 at one-tenth the concentration found in the hospital potable water. These findings support the recommendation that only sterile fluids be used for filling or cleaning respiratory care equipment and suggest that this guideline is not universally followed.
引用
收藏
页码:667 / 671
页数:5
相关论文
共 15 条
[1]   NOSOCOMIAL LEGIONNAIRES-DISEASE CAUSED BY AEROSOLIZED TAP WATER FROM RESPIRATORY DEVICES [J].
ARNOW, PM ;
CHOU, T ;
WEIL, D ;
SHAPIRO, EN ;
KRETZSCHMAR, C .
JOURNAL OF INFECTIOUS DISEASES, 1982, 146 (04) :460-467
[2]   DETECTION AND RECOVERY OF LEGIONELLA IN WATER [J].
BARBAREE, JM ;
MORRILL, WE ;
FIELDS, BS ;
MARTIN, WT ;
SANDEN, GN .
TOXICITY ASSESSMENT, 1988, 3 (05) :479-490
[3]   NOSOCOMIAL LEGIONNAIRES-DISEASE IN A CHILDRENS HOSPITAL [J].
BRADY, MT .
JOURNAL OF PEDIATRICS, 1989, 115 (01) :46-50
[4]   ASSOCIATION OF SHOWER USE WITH LEGIONNAIRES-DISEASE - POSSIBLE ROLE OF AMEBAS [J].
BREIMAN, RF ;
FIELDS, BS ;
SANDEN, GN ;
VOLMER, L ;
MEIER, A ;
SPIKA, JS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (21) :2924-2926
[5]   ROLE OF AIR SAMPLING IN INVESTIGATION OF AN OUTBREAK OF LEGIONNAIRES-DISEASE ASSOCIATED WITH EXPOSURE TO AEROSOLS FROM AN EVAPORATIVE CONDENSER [J].
BREIMAN, RF ;
COZEN, W ;
FIELDS, BS ;
MASTRO, TD ;
CARR, SJ ;
SPIKA, JS ;
MASCOLA, L .
JOURNAL OF INFECTIOUS DISEASES, 1990, 161 (06) :1257-1261
[6]   NEBULIZATION EQUIPMENT - A POTENTIAL SOURCE OF INFECTION IN GRAM-NEGATIVE PNEUMONIAS [J].
EDMONDSON, EB ;
REINARZ, JA ;
PIERCE, AK ;
SANFORD, JP .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1966, 111 (04) :357-+
[7]   EFFICACY OF COPPER AND SILVER IONS AND REDUCED LEVELS OF FREE CHLORINE IN INACTIVATION OF LEGIONELLA-PNEUMOPHILA [J].
LANDEEN, LK ;
YAHYA, MT ;
GERBA, CP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1989, 55 (12) :3045-3050
[8]   COMPARATIVE-ASSESSMENT OF CHLORINE, HEAT, OZONE, AND UV-LIGHT FOR KILLING LEGIONELLA-PNEUMOPHILA WITHIN A MODEL PLUMBING SYSTEM [J].
MURACA, P ;
STOUT, JE ;
YU, VL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (02) :447-453
[9]   BACTERIAL CONTAMINATION OF AEROSOLS [J].
PIERCE, AK ;
SANFORD, JP .
ARCHIVES OF INTERNAL MEDICINE, 1973, 131 (01) :156-159
[10]   LEGIONELLA IN WATER - WHAT SHOULD BE DONE [J].
REDD, SC ;
COHEN, ML .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 257 (09) :1221-1222