A GLUCOSE SENSOR FABRICATED BY THE SCREEN PRINTING TECHNIQUE

被引:67
作者
NAGATA, R
YOKOYAMA, K
CLARK, SA
KARUBE, I
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,TOKYO 153,JAPAN
[2] DAI NIPPON PRINTING CO LTD,CENT RES INST,KASHIWA,CHIBA 277,JAPAN
[3] JAPAN ADV INST SCI & TECHNOL,SCH MAT SCI,TATSUNOKUCHI,ISHIKAWA 92312,JAPAN
关键词
SENSOR; FERROCENE; FERROCENECARBOXYLIC ACID; GLUCOSE; GLUCOSE OXIDASE; PRINTING; SCREEN PRINTING; METAL MASK; SQUEEGEE;
D O I
10.1016/0956-5663(95)96845-P
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel glucose sensor employing ferrocene-modified glucose oxidase is fabricated using the screen printing technique. Glucose oxidase is covalently bound to the electron mediator ferrocenecarboxylic acid in order to obtain higher enzyme activity. The ferrocene-glucose oxidase shows an increased catalytic current because the ferrocene acts as an electron transfer relay between the active centre of the enzyme and the gold electrode. Glucose sensors employing enzymes modified with ferrocene in various ways are successfully fabricated using the screen printing technique. The ink component containing the ferrocene-glucose oxidase is specially developed to be applicable to the printing machine. The printed glucose sensor chip offers a stable calibration profile and stable electrochemical properties.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 20 条
  • [1] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    [J]. TALANTA, 1991, 38 (01) : 107 - 110
  • [2] ATANASOV P, 1992, BIOSENSORS BIOELECT, V1, P361
  • [3] ELECTROCHEMICAL INVESTIGATION OF NOVEL POLYMERIZABLE THIOPHENE FERROCENE CONJUGATES
    BACK, R
    LENNOX, RB
    [J]. LANGMUIR, 1992, 8 (03) : 959 - 964
  • [4] INTRAMOLECULAR ELECTRON-TRANSFER RATES IN FERROCENE-DERIVATIZED GLUCOSE-OXIDASE
    BADIA, A
    CARLINI, R
    FERNANDEZ, A
    BATTAGLINI, F
    MIKKELSEN, SR
    ENGLISH, AM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) : 7053 - 7060
  • [5] ENZYME ELECTRODE STUDIES OF GLUCOSE-OXIDASE MODIFIED WITH A REDOX MEDIATOR
    BARTLETT, PN
    BRADFORD, VQ
    WHITAKER, RG
    [J]. TALANTA, 1991, 38 (01) : 57 - 63
  • [6] GLUCOSE BIOSENSORS BASED ON THICK-FILM TECHNOLOGY
    BILITEWSKI, U
    RUGER, P
    SCHMID, RD
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (04) : 369 - 373
  • [7] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [8] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [9] DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .2. METHODS FOR BONDING ELECTRON-TRANSFER RELAYS TO GLUCOSE-OXIDASE AND D-AMINO-ACID OXIDASE
    DEGANI, Y
    HELLER, A
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) : 2615 - 2620
  • [10] DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME
    DEGANI, Y
    HELLER, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) : 1285 - 1289