INDOOR AIR-QUALITY AND ENVIRONMENTAL TOBACCO-SMOKE - CONCENTRATION AND EXPOSURE

被引:52
作者
HOLCOMB, LC
机构
[1] Holcomb Environmental Services, Olivet, MI 49076
关键词
Environmental tobacco smoke - Indoor air health risk - Indoor air quality monitoring - Lung cancer risk assessment - Permissible smoke particle doses - Tobacco smoke health impact;
D O I
10.1016/0160-4120(93)90004-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Environmental tobacco smoke (ETS) is often cited as a key factor in indoor air quality (IAQ) and public health. However, there are few studies which attempt to actually calculate the impact ETS has on IAQ or the doses of ETS one may receive from possible exposure in a variety of different settings. This paper reviews the data on indoor air published since 1980 and estimates the portion of various constituents which are produced by ETS. It can be observed that, in most instances, ETS has only a minor impact on IAQ. Retained doses of ETS particles are calculated for various exposure scenarios using respirable particle concentrations associated with ETS, time activity patterns, respiration rates and retention rates. Total doses range from 3-40 mg/y. This dose level does not seem to support the summary relative risk of 1.35 that has been claimed from meta-analyses of epidemiologic studies of spousal smoke exposure and lung cancer
引用
收藏
页码:9 / 40
页数:32
相关论文
共 106 条
[51]  
Morey, Jenkins, What are typical concentrations of fungi, total volatile organic compounds, and nitrogen dioxide in an office environment? The human equation: health and comfort, Proc. ASHRAE/SOEH conf., pp. 67-71, (1989)
[52]  
Moschandreas, Relwani, Luebcke, Fugitive emissions of NO<sub>2</sub> from vented gas appliances in residences—a pilot study, J. Air Waste Manage., 40, pp. 359-361, (1990)
[53]  
Mumford, Et al., Unvented kerosene heater emissions in mobil homes: studies on indoor air particles, semivolatile organics, carbon monoxide, and mutagenicity, Proc. 5th int. conf. on indoor air quality and climate, 2, pp. 257-262, (1990)
[54]  
NRC (National Research Council), Environmental tobacco smoke, measuring exposures and assessing health effects, (1986)
[55]  
NTP (National Toxicology Program), Proc. 5th annual report on carcinogens: summary 1989, (1989)
[56]  
Ogden, Maiolo, Collection and determination of solanesol as a tracer of environmental tobacco smoke in indoor air, Environ. Sci. Technol., 23, pp. 1148-1154, (1989)
[57]  
Oldaker, Perfetti, Conrad, Conner, McBride, Results from surveys of environmental tobacco smoke in offices and restaurants, Indoor air quality, pp. 99-104, (1990)
[58]  
Ozkaynak, Et al., Personal exposure to particulate matter: findings from the particle total exposure assessment methodology (PTEAM) prepilot study, Proc. 5th int. conference on indoor air quality and climate, 2, pp. 571-576, (1990)
[59]  
Petreas, Liu, Chang, Hayward, Sexton, A survey of nitrogen dioxide levels measured inside mobile homes, J. Air Pollut. Control Assoc., 38, pp. 647-651, (1988)
[60]  
Pleil, Oliver, McClenny, Volatile organic compounds in indoor air: a survey of various structures, Indoor air quality in cold climates, APCA, pp. 237-249, (1986)