HEAT-INDUCED CHANGES IN THE MECHANICAL-BEHAVIOR OF PASSIVE CORONARY-ARTERIES

被引:51
作者
KANG, T [1 ]
RESAR, J [1 ]
HUMPHREY, JD [1 ]
机构
[1] JOHNS HOPKINS UNIV,DEPT MED,BALTIMORE,MD 21205
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1995年 / 117卷 / 01期
关键词
D O I
10.1115/1.2792274
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We performed in vitro pressure-diameter and axial force-length experiments on nondiseased, passive bovine coronary arteries subjected to bath temperatures from 21 to 80 degrees C for 90 s to 4 hr. Over the strain ranges studied, we found that: (a) vessel behavior remained the same over 20 min of testing at 21 to 55 degrees C, (b) vessels stiffened multiaxially after 5 min of exposure to 60 degrees C and continued to stiffen over 20 min of testing, (c) dramatic multiaxial vessel stiffening and shrinkage occurred after 90 s of exposure to 70 and 80 degrees C, and (d) heat-induced changes at 70 degrees C depended on the intraluminal pressure during heating. Thus, passive bovine coronary arteries exhibit a complex thermomechanical behavior that depends on the temperature, duration of thermal exposure, and the mechanical loads applied during heating.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 37 条
  • [11] GORISCH W, 1981, LASER SURG MED, V2, P1
  • [12] HIELE JF, 1985, AM J CARDIOL, V56, P953
  • [13] THE ELASTIC PROPERTIES OF ELASTIN
    HOEVE, CAJ
    FLORY, PJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1959, 80 (24) : 6523 - 6526
  • [14] HOFFMAN JIE, 1990, CORONARY CIRCULATION
  • [15] HUMPHREY JD, 1989, BIORHEOLOGY, V26, P687
  • [16] COMPUTER-AIDED VASCULAR EXPERIMENTATION - A NEW ELECTROMECHANICAL TEST SYSTEM
    HUMPHREY, JD
    KANG, T
    SAKARDA, P
    ANJANAPPA, M
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (01) : 33 - 43
  • [17] MECHANICAL-BEHAVIOR OF EXCISED CANINE VISCERAL PLEURA
    HUMPHREY, JD
    VAWTER, DL
    VITO, RP
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (05) : 451 - 466
  • [18] LASER BALLOON ANGIOPLASTY - TECHNICAL REALIZATION AND VASCULAR TISSUE EFFECTS OF A MODIFIED CONCEPT
    ISCHINGER, T
    COPPENRATH, K
    WEBER, H
    ENDERS, S
    RUPRECHT, L
    UNSOLD, E
    HESSEL, S
    [J]. LASERS IN SURGERY AND MEDICINE, 1990, 10 (02) : 112 - 123
  • [19] LASER BALLOON ANGIOPLASTY VERSUS BALLOON ANGIOPLASTY IN NORMAL RABBIT ILIAC ARTERIES
    JENKINS, RD
    SINCLAIR, IN
    LEONARD, BM
    SANDOR, T
    SCHOEN, FJ
    SPEARS, JR
    [J]. LASERS IN SURGERY AND MEDICINE, 1989, 9 (03) : 237 - 247
  • [20] LASER BALLOON ANGIOPLASTY - EFFECT OF TISSUE TEMPERATURE ON WELD STRENGTH OF HUMAN POSTMORTEM INTIMA-MEDIA SEPARATIONS
    JENKINS, RD
    SINCLAIR, IN
    ANAND, R
    KALIL, AG
    SCHOEN, FJ
    SPEARS, JR
    [J]. LASERS IN SURGERY AND MEDICINE, 1988, 8 (01) : 30 - 39