MORPHOMETRIC ANALYSIS OF THE PERIPHERAL-NERVE - ADVANTAGES OF THE SEMIAUTOMATED INTERACTIVE METHOD

被引:22
作者
MEZIN, P [1 ]
TENAUD, C [1 ]
BOSSON, JL [1 ]
STOEBNER, P [1 ]
机构
[1] CHU GRENOBLE,SERV INFORMAT & INFORMAT MED,F-38043 GRENOBLE 9,FRANCE
关键词
MORPHOMETRY; PERIPHERAL NERVE; NERVE FIBER; IMAGE ANALYZER; SEMIAUTOMATED ANALYSIS;
D O I
10.1016/0165-0270(94)90006-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A semi-automated interactive method (BIOCOM) was developed for the morphometric analysis of the peripheral nerve in routine histopathoiogical examination. The human superficial peroneal nerve was used for myelinated fibre measurements. The precision and reproducibility of the results were validated using a manual morphometric method on a digitalizing table. Having compared the two methods, we believe that the semi-automated method constitutes an interesting alternative to traditional methods.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 22 条
[21]  
VITAL C, 1980, ULTRASTRUCTURAL STUD
[22]   IMAGING-SYSTEM FOR NERVE AND FIBER TRACT MORPHOMETRY - COMPONENTS, APPROACHES, PERFORMANCE, AND RESULTS [J].
ZIMMERMAN, IR ;
KARNES, JL ;
OBRIEN, PC ;
DYCK, PJ .
JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 1980, 39 (04) :409-419