ESTIMATION OF FETAL VOLUME BY MAGNETIC-RESONANCE-IMAGING AND STEREOLOGY

被引:103
作者
ROBERTS, N
GARDEN, AS
CRUZORIVE, LM
WHITEHOUSE, GH
EDWARDS, RHT
机构
[1] UNIV LIVERPOOL,MAGNET RESONANCE RES CTR,LIVERPOOL L69 3BX,MERSEYSIDE,ENGLAND
[2] UNIV BERN,DEPT ANAT,STEREOL UNIT,CH-3000 BERN 9,SWITZERLAND
关键词
D O I
10.1259/0007-1285-67-803-1067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current methods to monitor fetal growth in utero are based on ultrasound image measurements which, lacking a proper sampling methodology, may be biased to unknown degrees. The Cavalieri method of stereology guarantees the accurate estimation of the volume of an arbitrary object from a few systematic sections. Non-invasive scanning methods, and magnetic resonance imaging (MRI) in particular, are valuable tools to provide the necessary sections, and therefore offer interesting possibilities for unbiased quantification. This paper describes how to estimate fetal volume in utero with a coefficient of error of less than 5% in less than 5 min, from three or four properly sampled MRI scans. MRI was chosen because it does not use ionizing radiations on the one hand, and it offers a good image quality on the other. The impact of potential sources of bias such as fetal motion, chemical shift and partial voluming artefacts is discussed. The methods are illustrated on four subjects monitored between weeks 28 and 40 of gestation.
引用
收藏
页码:1067 / 1077
页数:11
相关论文
共 35 条
[11]   COMPARISON OF SEMIAUTOMATIC DIGITIZER-TABLET AND SIMPLE POINT COUNTING PERFORMANCE IN MORPHOMETRY [J].
GUNDERSEN, HJG ;
BOYSEN, M ;
REITH, A .
VIRCHOWS ARCHIV B-CELL PATHOLOGY INCLUDING MOLECULAR PATHOLOGY, 1981, 37 (03) :317-325
[12]   ESTIMATION OF FETAL WEIGHT WITH THE USE OF HEAD, BODY, AND FEMUR MEASUREMENTS - A PROSPECTIVE-STUDY [J].
HADLOCK, FP ;
HARRIST, RB ;
SHARMAN, RS ;
DETER, RL ;
PARK, SK .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 151 (03) :333-337
[13]  
JOHNSON IR, 1984, AM J OBSTET GYNECOL, V148, P1136, DOI 10.1016/0002-9378(84)90642-2
[14]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[15]  
Matheron G, 1965, VARIABLES REGIONALIS
[16]  
Matheron G, 1971, CAHIERS CTR MORPHOLO, V5
[17]   MEASURING ERROR AND SAMPLING VARIATION IN STEREOLOGY - COMPARISON OF THE EFFICIENCY OF VARIOUS METHODS FOR PLANAR IMAGE-ANALYSIS [J].
MATHIEU, O ;
CRUZORIVE, LM ;
HOPPELER, H ;
WEIBEL, ER .
JOURNAL OF MICROSCOPY, 1981, 121 (JAN) :75-88
[18]   METHODOLOGICAL PROBLEMS IN PLACENTAL MORPHOMETRY - APOLOGIA FOR THE USE OF STEREOLOGY BASED ON SOUND SAMPLING PRACTICE [J].
MAYHEW, TM ;
BURTON, GJ .
PLACENTA, 1988, 9 (06) :565-581
[19]  
MAYHEW TM, 1991, J ANAT, V178, P133
[20]  
MCROBBIE D, 1985, Magnetic Resonance Imaging, V3, P231, DOI 10.1016/0730-725X(85)90351-0