THERMAL-DIFFUSIVITY OF SKIN MEASURED BY 2 PHOTOTHERMAL TECHNIQUES

被引:41
作者
BROWN, SM [1 ]
BAESSO, ML [1 ]
SHEN, J [1 ]
SNOOK, RD [1 ]
机构
[1] UNIV MANCHESTER, INST SCI & TECHNOL, DEPT INSTRUMENTAT & ANALYT SCI, MANCHESTER M60 1QD, ENGLAND
关键词
PHOTOTHERMAL BEAM DEFLECTION; SKIN; THERMAL DIFFUSIVITY; THERMAL LENS SPECTROMETRY;
D O I
10.1016/0003-2670(93)80136-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The thermal diffusivity of pig abdomen stratum corneum has been determined using photothermal beam deflection measurements and time-resolved mode mismatched thermal lens spectrometry. The most precise determination (2.9+/-0.5x10(-4) cm(2) s(-1)) was obtained using the thermal lens technique. The practical utility of both techniques is discussed.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 16 条
[11]  
SENNHENN B, 1988, PHOTOACOUSTIC PHOTOT, P548
[12]   A RADIAL FINITE-MODEL OF THERMAL LENS SPECTROMETRY AND THE INFLUENCE OF SAMPLE RADIUS UPON THE VALIDITY OF THE RADIAL INFINITE-MODEL [J].
SHEN, J ;
SNOOK, RD .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (10) :5286-5288
[13]  
Shen J, 1989, ANAL PROC, V26, P403
[14]  
SHEN J, 1993, UNPUB PHYS REV B
[15]   FREE O-H OVERTONE ABSORPTION OF METHANOLS IN VISIBLE REGION BY THERMAL LENSING SPECTROSCOPY [J].
SWOFFORD, RL ;
LONG, ME ;
BURBERRY, MS ;
ALBRECHT, AC .
JOURNAL OF CHEMICAL PHYSICS, 1977, 66 (02) :664-668
[16]   MEASUREMENT OF THE THERMAL-DIFFUSIVITY OF HUMAN EPIDERMIS BY STUDYING THERMAL WAVE-PROPAGATION [J].
WERNER, U ;
GIESE, K ;
SENNHENN, B ;
PLAMANN, K ;
KOLMEL, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :21-35