CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION FOR DETECTING ALTERATIONS IN CARDIAC-OUTPUT AFTER DISCONTINUATION OF CARDIOPULMONARY BYPASS

被引:18
作者
INOMATA, S [1 ]
NISHIKAWA, T [1 ]
TAGUCHI, M [1 ]
机构
[1] UNIV TSUKUBA,INST CLIN MED,DEPT ANAESTHESIOL,TSUKUBA,IBARAKI 305,JAPAN
关键词
BLOOD; HEMOGLOBIN SATURATION; EQUIPMENT; FIBEROPTIC PULMONARY ARTERY CATHETER; OXIMETER; HEART; CARDIAC INDEX; CARDIAC OUTPUT; MONITORING; OXYGEN; CONSUMPTION; SATURATION;
D O I
10.1093/bja/72.1.11
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Although mixed venous oxygen saturation (S $($) over bar$$ v(o2)) is related to the reciprocal of cardiac output (CO) if both arterial oxygen content and oxygen consumption remain constant, simultaneous alterations in the three variables may occur immediately after discontinuation of cardiopulmonary bypass (CPB). To examine if continuous monitoring of S $($) over bar$$ v (O2) using a fibreoptic pulmonary artery catheter would be useful for detecting alterations in CO immediately after discontinuation of CPB, we have examined the relationships between changes in S $($) over bar$$ v(O2) cardiac index (Cl), oxygen consumption and haemoglobin concentration in 15 cardiac surgical patients. Changes in S $($) over bar$$ v(O2) correlated well with those in Cl for 60 min after CPB (r = 0.75, P = 0.0001). A closer correlation between these two variables was noted in the patients with baseline Cl of less than 2 litre min(-1) m(-2) (r = 0.87) than the patients with baseline Cl of more than 2 litre min(-1) m(-2) (r = 0.66). However, changes in S $($) over bar$$ v(O2) did not correlate with either oxygen consumption or haemoglobin concentration. The current results suggest that continuous monitoring of S $($) over bar$$ v(O2), with the fibreoptic pulmonary artery catheter may be useful for detecting changes in CO after discontinuation of CPB in patients with compromized cardiac function: (Br. J. Anaesth. 1994; 72: 11-16)
引用
收藏
页码:11 / 16
页数:6
相关论文
共 31 条
[1]  
BAELE PL, 1982, ANESTH ANALG, V61, P513
[2]   CATHETER MEASUREMENT OF MIXED VENOUS OXYGEN-SATURATION [J].
BAILLY, R ;
JASTREMSKI, MS ;
CHELLURI, L .
CRITICAL CARE MEDICINE, 1985, 13 (08) :695-695
[3]   EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY [J].
BARKER, SJ ;
TREMPER, KK ;
HYATT, J .
ANESTHESIOLOGY, 1989, 70 (01) :112-117
[4]   CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN HEMODYNAMICALLY UNSTABLE PATIENTS [J].
BIRMAN, H ;
HAQ, A ;
HEW, E ;
ABERMAN, A .
CHEST, 1984, 86 (05) :753-756
[5]   ESTIMATION OF CARDIAC OUTPUT SOON AFTER INTRACARDIAC SURGERY WITH CARDIOPULMONARY BYPASS [J].
BOYD, AD ;
TREMBLAY, RE ;
SPENCER, FC ;
BAHNSON, HT .
ANNALS OF SURGERY, 1959, 150 (04) :613-626
[6]   BLOOD-GAS TENSIONS AND PH OF PULMONARY WEDGE SAMPLES IN PATIENTS WITH HEART-DISEASE [J].
BREWSTER, H ;
MCILROY, MB .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (04) :413-416
[7]  
DELAROCHA AG, 1978, CAN J SURG, V21, P227
[8]   CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION [J].
DIVERTIE, MB ;
MCMICHAN, JC .
CHEST, 1984, 85 (03) :423-428
[9]   CLINICAL-EXPERIENCE WITH CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN RESPIRATORY-FAILURE [J].
FAHEY, PJ ;
HARRIS, K ;
VANDERWARF, C .
CHEST, 1984, 86 (05) :748-752
[10]  
GILBERT HC, 1992, CLIN ANESTH, P756