THE APPLICATION OF HYBRID MASS-SPECTROMETRY MASS-SPECTROMETRY AND HIGH-RESOLUTION MASS-SPECTROMETRY TO THE ANALYSIS OF FISH SAMPLES FOR POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS

被引:15
作者
HUANG, LQ
EITZER, B
MOORE, C
MCGOWN, S
TOMER, KB
机构
[1] KRATOS ANALYT INC,RAMSEY,NJ 07446
[2] NIEHS,RES TRIANGLE PK,NC 27709
关键词
D O I
10.1002/bms.1200200402
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A hybrid mass spectrometer operated in low-resolution selected decomposition monitoring (SDM) mode was used for the analysis of whole fish samples for the 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). These fish samples were previously analyzed for PCDD/Fs using a high-resolution mass spectrometer following EPA protocols. The hybrid tandem mass spectrometric method using loss of COCl gave similar quantification results to those obtained by high-resolution mass spectrometry and eliminated the interferences attributed to polychlorinated biphenyls that were encountered in the high-resolution mass spectrometric analysis. Comparison of the two methods shows that the high-resolution mass spectrometric method surpasses the tandem mass spectrometric method in other analytical figures of merit, such as detection limit, linearity and reproducibility.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 30 条
[1]  
ALBORO PW, 1985, ANAL CHEM, V57, P2717
[2]  
BAUGHMAN R, 1973, Environmental Health Perspectives, V5, P27, DOI 10.2307/3428110
[3]  
BAUGHMAN RW, 1971, 162ND ANN NAT ACS M
[4]   OPTIMIZATION OF A HYBRID-MASS SPECTROMETER METHOD FOR THE ANALYSIS OF POLYCHLORINATED DIBENZO-P-DIOXINS AND POLYCHLORINATED DIBENZOFURANS [J].
CHARLES, MJ ;
GREEN, B ;
TONDEUR, Y ;
HASS, JR .
CHEMOSPHERE, 1989, 19 (1-6) :51-57
[5]  
CHESS EK, 1989, ANAL CHEM, V52, P2057
[6]   COMPARISON OF INSTRUMENTAL METHODS FOR CHLORINATED DIBENZO-P-DIOXIN (CDD) DETERMINATION - INTERIM RESULTS OF A ROUND-ROBIN STUDY INVOLVING GC-MS, MS-MS, AND HIGH-RESOLUTION MS [J].
CLEMENT, RE ;
BOBBIE, B ;
TAGUCHI, V .
CHEMOSPHERE, 1986, 15 (9-12) :1147-1156
[7]   MEASUREMENT PARAMETER SELECTION FOR QUANTITATIVE ISOTOPE-DILUTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
COLBY, BN ;
ROSECRANCE, AE ;
COLBY, ME .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1907-1911
[8]  
CRUMMETT WB, 1987, PCDD PCDF LEVELS MEA
[9]   COMPUTER MODELING OF FRAGMENTATION PROCESSES IN RADIO-FREQUENCY MULTIPOLE COLLISION CELLS [J].
DAVIS, SC ;
WRIGHT, B .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (06) :186-197
[10]   ATMOSPHERIC TRANSPORT AND DEPOSITION OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS [J].
EITZER, BD ;
HITES, RA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (11) :1396-1401