EFFECTIVENESS OF ORTHOTIC SHOE INSERTS IN THE LONG-DISTANCE RUNNER

被引:100
作者
GROSS, ML
DAVLIN, LB
EVANSKI, PM
机构
[1] Orthopaedic and Sports Medicine Associates, Emerson, New Jersey
关键词
D O I
10.1177/036354659101900416
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Five hundred questionnaires were distributed to long-distance runners who had used, or who were using orthotic shoe inserts for symptomatic relief of lower extremity complaints. Three hundred forty-seven (69.4%) responded (males, 71%; females, 29%). The mean age of the respondents were 36 years (range, 15 to 61). The average distance run per week was 39.6 miles (range, 5 to 98). The mean duration for use of the orthotic inserts was 23 months (range, 1 to 96). The predominant (63%) type of orthotic device used was flexible. The presumed diagnoses in the population studied were excessive pronation (31.1%), leg length discrepancy (13.5%), patellofemoral disorders (12.6%), plantar fasciitis (20.7%), Achilles tendinitis (18.5%), shin splints (7.2%), and miscellaneous (4.9%). Of the runners responding, 262 (75.5%) reported complete resolution or great improvement of their symptoms. Results of treatment with orthotic shoe inserts were independent of the diagnosis or the runner's level of participation. A high degree of overall satisfaction was demonstrated by the finding that 90% of the runners continued to use the orthotic devices even after resolution of their symptoms. Orthotic shoe inserts were most effective in the treatment of symptoms arising from biomechanical abnormalities, such as excessive pronation or leg length discrepancy. Along with other conservative measures, orthotic shoe inserts may allow the athlete to continue participation in running and avoid other treatment modalities that are more costly and time consuming, and therefore less acceptable to them.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 19 条
[11]  
James S.L., Brubaker C.E., Biomechanics of running, Orthop Clin North Am, 4, pp. 605-615, (1973)
[12]  
Lutter L.D., Cavus foot in runners, Foot Ankle, 1, pp. 228-255, (1981)
[13]  
Lutter L.D., Foot-related knee problems in the long distance runner, Foot Ankle, 1, pp. 112-116, (1980)
[14]  
Lysholm J., Wikiander J., Am J Sports Med, 15, pp. 168-171, (1987)
[15]  
Mann R.A., Baxter D.E., Lutter L.D., Running symposium Foot Ankle, 1, pp. 190-244, (1981)
[16]  
Nigg B.M., Herzog W., Read L.J., Effect of viscoelastic shoe insoles on vertical impact forces in heel-toe running, Am J Sports Med, 16, pp. 70-76, (1988)
[17]  
Schuster R.O., Root types and the influence of the environment on the foot of the long distance runner, Ann NY Acad Sci, 301, pp. 881-887, (1977)
[18]  
Scranton P.E., Pedegania L.R., Whitesel J.P., Alterations in support phase forces using supporting devices, Am J Sports Med, 10, pp. 6-10, (1982)
[19]  