DEVELOPMENT AND COMPARISON OF DIFFERENT FLUOROMETRIC HPLC-METHODS WITH STANDARD METHODS FOR THE DETERMINATION OF FORMALDEHYDE IN THE ATMOSPHERE

被引:9
作者
GROMPING, AHJ [1 ]
CAMMANN, K [1 ]
机构
[1] UNIV MUNSTER,INST ANORGAN CHEM,LEHRSTUHL ANALYT CHEM,W-4400 MUNSTER,GERMANY
关键词
COLUMN LIQUID CHROMATOGRAPHY; FORMALDEHYDE IN AIR; FLUOROMETRIC DETECTION; COMPARISON OF FLUORESCENT DERIVATIVES;
D O I
10.1007/BF02269693
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three different fluorimetric methods for the measurement of atmospheric formaldehyde are described. The relatively unknown 2-diphenylacetylindan-1,3-dionhydrazine (DAIH) method was developed and optimized with an improved limit of detection of 2 ppbv corresponding to a sample volume of 7.5 L. Separation of lutidines necessary for the Nash method was successfully carried out and the separation time was reduced by a factor of 5. The detection limit of the Nash method was improved to 1 ppbv. In comparison, the N,N-diphenyl-1-naphthylamine-5-sulfonhydrazine (DNSH) method performed in a similar manner, reached an LOD of 0.5 ppbv. Finally, measurements made in candle smoke using the three different fluorimetric methods and three standard methods yielded very similar results.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 33 条
[31]  
DFG ANAL METHODEN PR, V1
[32]  
1977, DHHS NIOSH77157A P C
[33]  
1985, BUNDESANSTALT ARBEIT