MICROPORE MEMBRANE INLET MASS-SPECTROMETER PROBES SUITABLE FOR MEASUREMENT OF TISSUE SURFACE GAS TENSIONS

被引:23
作者
BAUMGARDNER, JE
QUINN, JA
NEUFELD, GR
机构
[1] UNIV PENN,DEPT BIOENGN,PHILADELPHIA,PA 19104
[2] UNIV PENN,DEPT CHEM ENGN,PHILADELPHIA,PA 19104
来源
JOURNAL OF MASS SPECTROMETRY | 1995年 / 30卷 / 04期
关键词
D O I
10.1002/jms.1190300407
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New membrane inlet mass spectrometer (MIMS) probes are described that feature a micropore in a flat metal surface filled with a polymer membrane (Krytox high-vacuum fluorinated grease). In vitro assessment of spatial resolution, time response, stirring effect and calibration are reported. The small membrane area for this MIMS results in spatial resolution of about 30 mu m, adequate for measuring gas tensions at an exposed tissue surface in experimental studies of tissue oxygenation and tissue gas exchange. These probes offer a unique combination of minimal stirring effect and rapid response speed for measurements of gas partial pressures in the per cent range in aqueous solutions. Several gases, including oxygen, carbon dioxide, helium, sulfur hexafluoride and argon, permeate the polymer membrane to give a detectable signal, and the membrane is highly impermeable to water. Membrane dimensions were calculated from time response characteristics and the measured gas sample rate for argon. The membrane area was independently confirmed by direct assessment of spatial resolution. This MIMS is highly linear, has an excellent signal-to-noise ratio and offers practical advantages over electrode approaches to the measurement of gas tensions in aqueous solution.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 42 条
[1]   REGIONAL CEREBRAL BLOOD-FLOW AND TISSUE OXYGENATION DURING HYPOCAPNIA IN GEESE [J].
BICKLER, PE ;
JULIAN, D .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (02) :R221-R225
[2]  
BIER ME, 1990, ANAL CHIM ACTA, V31, P175
[3]   A NEW MICROELECTRODE METHOD FOR SIMULTANEOUS MEASUREMENT OF PH AND PCO2 [J].
BOMSZTYK, K ;
CALALB, MB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (05) :F933-F937
[4]   CLINICAL CATHETER FOR CONTINUOUS BLOOD-GAS MEASUREMENT BY MASS-SPECTROMETRY [J].
BRANTIGAN, JW ;
DUNN, KL ;
ALBO, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (03) :443-446
[5]   PTIO2 AND CMRO2 CHANGES IN CORTEX AND HIPPOCAMPUS OF AGING GERBIL BRAIN [J].
BUERK, DG ;
NAIR, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (04) :1723-1728
[6]  
CRANK J, 1968, DIFFUSION POLYM, P48
[7]   MEASUREMENTS OF THE PERIVASCULAR PO2 IN THE VICINITY OF THE PIAL VESSELS OF THE CAT [J].
DULING, BR ;
KUSCHINSKY, W ;
WAHL, M .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1979, 383 (01) :29-34
[8]  
ELLSWORTH ML, 1994, NEWS PHYSIOL SCI, V9, P119
[9]  
ELSWORTH ML, 1990, AM J PHYSIOL, V258, pH1240
[10]   O-2 GRADIENTS FROM SARCOLEMMA TO CELL INTERIOR IN RED MUSCLE AT MAXIMAL VO2 [J].
GAYESKI, TEJ ;
HONIG, CR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (04) :H789-H799