MICROPORE MEMBRANE INLET MASS-SPECTROMETER PROBES SUITABLE FOR MEASUREMENT OF TISSUE SURFACE GAS TENSIONS

被引:23
作者
BAUMGARDNER, JE
QUINN, JA
NEUFELD, GR
机构
[1] UNIV PENN,DEPT BIOENGN,PHILADELPHIA,PA 19104
[2] UNIV PENN,DEPT CHEM ENGN,PHILADELPHIA,PA 19104
来源
JOURNAL OF MASS SPECTROMETRY | 1995年 / 30卷 / 04期
关键词
D O I
10.1002/jms.1190300407
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New membrane inlet mass spectrometer (MIMS) probes are described that feature a micropore in a flat metal surface filled with a polymer membrane (Krytox high-vacuum fluorinated grease). In vitro assessment of spatial resolution, time response, stirring effect and calibration are reported. The small membrane area for this MIMS results in spatial resolution of about 30 mu m, adequate for measuring gas tensions at an exposed tissue surface in experimental studies of tissue oxygenation and tissue gas exchange. These probes offer a unique combination of minimal stirring effect and rapid response speed for measurements of gas partial pressures in the per cent range in aqueous solutions. Several gases, including oxygen, carbon dioxide, helium, sulfur hexafluoride and argon, permeate the polymer membrane to give a detectable signal, and the membrane is highly impermeable to water. Membrane dimensions were calculated from time response characteristics and the measured gas sample rate for argon. The membrane area was independently confirmed by direct assessment of spatial resolution. This MIMS is highly linear, has an excellent signal-to-noise ratio and offers practical advantages over electrode approaches to the measurement of gas tensions in aqueous solution.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 42 条
[31]  
POPEL AS, 1989, CRIT REV BIOMED ENG, V17, P257
[32]   TONOMETER FOR CALIBRATION AND EVALUATION OF OXYGEN MICRO-ELECTRODES [J].
PROCTOR, KG ;
BOHLEN, HG .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (05) :1016-1018
[33]   CEREBRAL OXYGEN-TENSION IN RATS DURING DELIBERATE HYPOTENSION WITH SODIUM-NITROPRUSSIDE, 2-CHLOROADENOSINE, OR DEEP ISOFLURANE ANESTHESIA [J].
SEYDE, WC ;
LONGNECKER, DE .
ANESTHESIOLOGY, 1986, 64 (04) :480-485
[34]   LOCAL CEREBRAL PO2, PCO2, AND BLOOD-FLOW MEASUREMENTS BY MASS-SPECTROMETRY [J].
SEYLAZ, J ;
PINARD, E ;
MERIC, P ;
CORREZE, JL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 245 (03) :H513-H518
[35]   QUANTITATIVE CONTINUOUS MEASUREMENT OF BLOOD-GAS TENSIONS BY MASS-SPECTROMETRY [J].
SEYLAZ, J ;
PINARD, E ;
CORREZE, JL ;
AUBINEAU, PF ;
MAMO, H .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (06) :937-941
[36]   RELATIONSHIP BETWEEN CAPILLARY AND SYSTEMIC VENOUS PO2 DURING NONHYPOXIC AND HYPOXIC VENTILATION [J].
STEIN, JC ;
ELLIS, CG ;
ELLSWORTH, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (02) :H537-H542
[37]   SKELETAL-MUSCLE OXYGEN-PRESSURE FIELDS DURING CONTROLLED HYPOTENSION WITH ADENOSINE AND SODIUM-NITROPRUSSIDE - A COMPARATIVE-STUDY IN THE RABBIT [J].
TORSSELL, L ;
SOLLEVI, A ;
THORBORG, P ;
LUND, N .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1986, 30 (01) :93-96
[38]   INTERSTITIAL PCO2 AND PH IN RAT HIPPOCAMPAL SLICES MEASURED BY MEANS OF A NOVEL FAST CO2/H+-SENSITIVE MICROELECTRODE BASED ON A PVC-GELLED MEMBRANE [J].
VOIPIO, J ;
KAILA, K .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1993, 423 (3-4) :193-201
[39]   NOVEL MASS-SPECTROMETRIC SAMPLING DEVICE - HOLLOW FIBER PROBE [J].
WESTOVER, LB ;
TOU, JC ;
MARK, JH .
ANALYTICAL CHEMISTRY, 1974, 46 (04) :568-571
[40]   A MICROELECTRODE FOR MEASURING INTRACELLULAR PO2 [J].
WHALEN, WJ ;
RILEY, J ;
NAIR, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 23 (05) :798-&