The practical aspects of a He microwave induced plasma (MIP) mass spectrometry system for the determination of As, Se, Br and I in biological samples were investigated. A prototype instrument with a toroidal helium MIP coupled to a quadrupole mass spectrometer was used. Liquid samples were analysed by pneumatic nebulization with a Meinhard nebulizer without desolvation. The plasma was operated at 380 W with 3.6 I min-1 cooling gas, 0.8 I min-1 nebulizer gas, 0.6 I min-1 intermediate gas and 0.5 ml min-1 sample uptake rate. Arsenic, Se, Br and I showed linearity of more than 4 orders of magnitude. The detection limits (3s) were determined for As-75, Se-78, Br-79 and I-127, and were 0.05, 0.25, 0.30 and 0.07 mug I-1, respectively. The influence of Na and K on the response of As was less than 20% up to concentrations of 1000 mg I-1. Analysis of 3% HCl causes an interference at a concentration of 1 mug I-1 of As, analysis of 1000 mg I-1 of Ca causes an interference at a concentration of 2 mug I-1 of As. Both of these elements in the solution cause significant interference in the determination of As-75, due to the formation of the Ca-40-Cl-35 polyatomic ion. Biological reference materials (liver, muscle, milk, flour, diet and fish) and different fish samples were analysed for As and Se after high-pressure ashing with HNO3. Bromine was found to be a good internal standard for these elements. The results obtained with the He-MIP showed good agreement with the certified values for most of the materials investigated. Bromine and I were determined after alkaline digestion with tetramethylammonium hydroxide. The determination of Br was complicated by severe memory effects. The results obtained for the few available reference materials showed acceptable agreement with the certified values.
引用
收藏
页码:1021 / 1027
页数:7
相关论文
共 25 条
[1]   ELECTROTHERMAL VAPORIZATION AND ULTRASONIC NEBULIZATION FOR THE DETERMINATION OF AQUEOUS SULFUR USING A KILOWATT-PLUS HELIUM MICROWAVE-INDUCED PLASMA [J].
ALVARADO, J ;
WU, MG ;
CARNAHAN, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1253-1256
[2]   APPLICATION OF HELIUM MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRY TO THE DETECTION OF HIGH IONIZATION-POTENTIAL GAS-PHASE SPECIES [J].
BROWN, PG ;
DAVIDSON, TM ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :763-769
[3]   FUNDAMENTAL-STUDIES OF THE SAMPLING PROCESS IN AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER .4. REPLACEMENT OF THE INDUCTIVELY COUPLED PLASMA WITH A HELIUM MICROWAVE-INDUCED PLASMA [J].
CHAMBERS, DM ;
CARNAHAN, JW ;
JIN, Q ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1745-1765
[4]   HELIUM MICROWAVE INDUCED PLASMA MASS-SPECTROMETRY FOR DETECTION OF METALS AND NONMETALS IN AQUEOUS-SOLUTIONS [J].
CREED, JT ;
DAVIDSON, TM ;
SHEN, WL ;
BROWN, PG ;
CARUSO, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (09) :909-924
[5]   A STUDY OF PNEUMATIC NEBULIZATION WITH HELIUM [J].
CULL, KB ;
CARNAHAN, JW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (05) :629-635
[6]  
DATE AR, 1989, APPLICATIONS INDUCTI
[7]   ELEMENTAL ANALYSIS WITH A MICROWAVE-INDUCED PLASMA-QUADRUPOLE MASS-SPECTROMETER SYSTEM [J].
DOUGLAS, DJ ;
FRENCH, JB .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :37-41
[8]   ELEMENTAL ANALYSIS WITH AN ATMOSPHERIC-PRESSURE PLASMA (MIP, ICP) QUADRUPOLE MASS-SPECTROMETER SYSTEM [J].
DOUGLAS, DJ ;
QUAN, ESK ;
SMITH, RG .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (1-2) :39-48
[9]   DIRECTLY COUPLED CHROMATOGRAPHY - ATOMIC SPECTROSCOPY .1. DIRECTLY COUPLED GAS-CHROMATOGRAPHY - ATOMIC SPECTROSCOPY - A REVIEW [J].
EBDON, L ;
HILL, S ;
WARD, RW .
ANALYST, 1986, 111 (10) :1113-1138
[10]   STUDY OF A TOROIDAL ARGON AND A CYLINDRICAL HELIUM MICROWAVE INDUCED PLASMA FOR ANALYTICAL ATOMIC EMISSION-SPECTROMETRY .1. CONFIGURATIONS AND SPECTROSCOPIC PROPERTIES [J].
HELTAI, G ;
BROEKAERT, JAC ;
LEIS, F ;
TOLG, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (03) :301-311