TRACE ANALYSIS IN HIGH MATRIX AQUEOUS-SOLUTIONS USING HELIUM MICROWAVE-INDUCED PLASMA-MASS SPECTROMETRY

被引:34
作者
FECHER, PA
NAGENGAST, A
机构
[1] Landesuntersuchungsamt f.d. Gesundheitswesen Nordbayern, D-91054 Erlangen
关键词
HELIUM MICROWAVE INDUCED PLASMA MASS SPECTROMETRY; ARSENIC; SELENIUM; BROMINE AND IODINE DETERMINATION; BIOLOGICAL SAMPLES; POLYATOMIC INTERFERENCES;
D O I
10.1039/ja9940901021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The practical aspects of a He microwave induced plasma (MIP) mass spectrometry system for the determination of As, Se, Br and I in biological samples were investigated. A prototype instrument with a toroidal helium MIP coupled to a quadrupole mass spectrometer was used. Liquid samples were analysed by pneumatic nebulization with a Meinhard nebulizer without desolvation. The plasma was operated at 380 W with 3.6 I min-1 cooling gas, 0.8 I min-1 nebulizer gas, 0.6 I min-1 intermediate gas and 0.5 ml min-1 sample uptake rate. Arsenic, Se, Br and I showed linearity of more than 4 orders of magnitude. The detection limits (3s) were determined for As-75, Se-78, Br-79 and I-127, and were 0.05, 0.25, 0.30 and 0.07 mug I-1, respectively. The influence of Na and K on the response of As was less than 20% up to concentrations of 1000 mg I-1. Analysis of 3% HCl causes an interference at a concentration of 1 mug I-1 of As, analysis of 1000 mg I-1 of Ca causes an interference at a concentration of 2 mug I-1 of As. Both of these elements in the solution cause significant interference in the determination of As-75, due to the formation of the Ca-40-Cl-35 polyatomic ion. Biological reference materials (liver, muscle, milk, flour, diet and fish) and different fish samples were analysed for As and Se after high-pressure ashing with HNO3. Bromine was found to be a good internal standard for these elements. The results obtained with the He-MIP showed good agreement with the certified values for most of the materials investigated. Bromine and I were determined after alkaline digestion with tetramethylammonium hydroxide. The determination of Br was complicated by severe memory effects. The results obtained for the few available reference materials showed acceptable agreement with the certified values.
引用
收藏
页码:1021 / 1027
页数:7
相关论文
共 25 条
[21]   DETECTION OF HALOGENS AS POSITIVE-IONS USING A HE MICROWAVE INDUCED PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRY [J].
SATZGER, RD ;
FRICKE, FL ;
BROWN, PG ;
CARUSO, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (05) :705-712
[22]   ELEMENTAL MASS-SPECTROMETRY USING A MODERATE POWER MICROWAVE-INDUCED PLASMA AS AN ION-SOURCE [J].
SATZGER, RD ;
FRICKE, FL ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :319-323
[23]  
SATZGER RD, 1989, MIKROCHIM ACTA, V3, P239
[24]   USE OF THE MICROWAVE-INDUCED NITROGEN DISCHARGE AT ATMOSPHERIC-PRESSURE AS AN ION-SOURCE FOR ELEMENTAL MASS-SPECTROMETRY [J].
WILSON, DA ;
VICKERS, GH ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1664-1670
[25]   DIRECT DETERMINATION OF AQUEOUS CARBON, PHOSPHORUS AND SULFUR USING A KILOWATT-PLUS HELIUM MICROWAVE-INDUCED PLASMA SYSTEM WITH ULTRASONIC NEBULIZATION [J].
WU, MG ;
CARNAHAN, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1249-1252