A 360-DEGREES SINGLE-AXIS TILT STAGE FOR THE HIGH-VOLTAGE ELECTRON-MICROSCOPE

被引:40
作者
BARNARD, DP [1 ]
TURNER, JN [1 ]
FRANK, J [1 ]
MCEWEN, BF [1 ]
机构
[1] UNIV ALBANY, SCH PUBL HLTH, ALBANY, NY 12201 USA
关键词
ELECTRON MICROSCOPY; EM STAGES; TILT STAGES; HVEM; TOMOGRAPHY; 3-DIMENSIONAL RECONSTRUCTION;
D O I
10.1111/j.1365-2818.1992.tb03217.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A new type of specimen stage that permits more than 180-degrees of tilting about the axis of a side-entry rod has been developed for a high-voltage electron microscope (HVEM). Roughly cylindrical specimens, with radial dimensions of less than a few micrometres, that can be mounted on the tip of a microneedle or micropipette are applicable. For glass micropipettes, the energy of the 1-MeV beam of the HVEM is sufficient to image specimens through both walls. The stage employs a spindle mechanism that holds these needles or micropipettes coaxial with the tilt axis, allowing the specimen to be rotated without restriction. This arrangement, along with the cylindrical form of the specimen, is an important development tor single-axis tomography, because it permits a complete 180-degrees set of projections to be recorded. The angular accuracy of the stage was demonstrated to be within +/- 0.20-degrees, with a cumulative error of less than 1.0-degrees over a 180-degrees span. The new stage was tested using puffball spores mounted on a micropipette. A 180-degrees tilt series was recorded and processed to yield a tomographic three-dimensional reconstruction which was displayed both as a cross-sectional view perpendicular to the tilt axis, and as a shaded surface viewed from different directions. The same computations were repeated using subsets of the tilt series to assess the effect of various amounts of missing information. Visual inspection of a selected cross-section from these reconstructions indicated that limiting the angular range to 160-degrees produced results nearly as good as the full data set. Limiting the range to 140-degrees, however, produced a noticeable geometric distortion, which became increasingly severe with ranges of 120-degrees and 100-degrees.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 34 条
  • [11] JEROME WG, 1987, AM J PATHOL, V128, P253
  • [12] ALIGNMENT OF TOMOGRAPHIC PROJECTIONS USING AN INCOMPLETE SET OF FIDUCIAL MARKERS
    JING, ZQ
    SACHS, F
    [J]. ULTRAMICROSCOPY, 1991, 35 (01) : 37 - 43
  • [13] LANDIS W J, 1990, Journal of Cell Biology, V111, p24A
  • [14] THE APPLICATION OF THE MAXIMUM-ENTROPY METHOD TO ELECTRON-MICROSCOPIC TOMOGRAPHY
    LAWRENCE, MC
    JAFFER, MA
    SEWELL, BT
    [J]. ULTRAMICROSCOPY, 1989, 31 (03) : 285 - 302
  • [15] LAWRENCE MC, 1992, IN PRESS ELECTRON TO, P197
  • [16] MCEWAN BF, 1992, IN PRESS ELECTRON TO, P281
  • [17] TOMOGRAPHIC 3-DIMENSIONAL RECONSTRUCTION OF CILIA ULTRASTRUCTURE FROM THICK SECTIONS
    MCEWEN, BF
    RADERMACHER, M
    RIEDER, CL
    FRANK, J
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (23) : 9040 - 9044
  • [18] MCEWEN BF, 1990, 12 P INT C EL MICR, V1, P522
  • [19] OLINS AL, 1984, EUR J CELL BIOL, V35, P129
  • [20] ELECTRON-MICROSCOPE TOMOGRAPHY - TRANSCRIPTION IN 3-DIMENSIONS
    OLINS, DE
    OLINS, AL
    LEVY, HA
    DURFEE, RC
    MARGLE, SM
    TINNEL, EP
    DOVER, SD
    [J]. SCIENCE, 1983, 220 (4596) : 498 - 500