RENAL DUPLEX SCANNING - CORRELATION WITH ANGIOGRAPHY AND ISOTOPIC RENOGRAPHY

被引:12
作者
MIRALLES, M
SANTISO, A
GIMENEZ, A
RIAMBAU, V
SAEZ, A
DAUMAL, J
CAIROLS, MA
机构
[1] Hospital Del Mar, Passeig Maritim 25, Universidad Autonoma De Barcelona
来源
EUROPEAN JOURNAL OF VASCULAR SURGERY | 1993年 / 7卷 / 02期
关键词
RENAL DUPLEX SCANNING; CAPTOPRIL TEST; ISOTOPIC RENOGRAM; RENOVASCULAR HYPERTENSION;
D O I
10.1016/S0950-821X(05)80761-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to assess the accuracy of Duplex scanning in detecting renovascular disease and to compare it with angiography, renal scintigraphy and captopril test for plasma renin activity and isotopic renography. A Duplex scan was performed in 92 renal arteries (46 patients) and compared to angiography. Three degrees of stenoses were established: 0-60%, 61-99% and occlusion. The peak systolic velocity (PSV) in the renal artery and its ratio to the peak velocity in the aorta (RAR) were used to discriminate stenoses >60%. PSV in the interlobar arteries was used to assess the relative perfusion of both parenchyma. Angiography demonstrated a stenoses >60% in 23 hypertensive patients. In all of the patients, plasma renin activity was measured and isotopic renograms (pre- and post-captopril) obtained in order to discriminate hypertension of vascular origin. A PSV in the renal artery >210 cm/s and a RAR >3.5 were found to be the diagnostic criteria with the best sensitivity and specificity in detecting stenoses >60%. Based on these data, Duplex correctly identified 49/54 stenoses >60%; 28/33 stenoses <60%; and 5/5 occlusions (kappa 0.79). Sensitivity and specificity in detecting stenoses >60% were 89.5 and 90.7%, respectively. The ratio between PSV in the interlobar arteries of both parenchyma accurately predicted the relative perfusion (ratio between DTPA uptake in both kidneys) in the isotopic test (n = 23, r = 0.91, p = 0.001). The captopril test (for plasma renin activity and isotopic renography) was positive in only five patients. Four of these had a unilateral stenosis and in the other the stenoses was bilateral. In all five patients angiography showed a renal artery stenoses >80%. In a sixth patient with bilateral stenosis and a normal isotopic renogram, captopril administration produced a significant increase in plasma renin activity. Renal Duplex scanning correlates well with angiography when grading renal artery stenoses and with scintigraphy when assessing renal vascular perfusion. However, the detection of renal artery stenoses in a hypertensive patient may not always mean renovascular hypertension. Renal Duplex scanning will probably not replace other screening methods such as the captopril test, but its integration into a diagnostic algorithm may permit a more selective role for renal angiography. © 1993 Grune & Stratton Ltd.
引用
收藏
页码:188 / 194
页数:7
相关论文
共 20 条
[11]  
Avasthi, Voyles, Greene, Noninvasive diagnosis of renal artery stenosis by echo-Doppler velocimetry, Kidney Int, 25, pp. 824-829, (1984)
[12]  
Kohler, Zierler, Martin, Nicholls, Bergelin, Kazmers, Beach, Strandness, Noninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning, J Vasc Surg, 4, pp. 450-456, (1986)
[13]  
Hoffmann, Edwards, Carter, Goldman, Harley, Zaccardi, Strandness, Role of duplex scanning for the detection of atherosclerotic renal artery disease, Kidney International, 39, pp. 1232-1239, (1991)
[14]  
Kollenberg, Renal hemodynamics in essential and renovascular hypertension, The American Journal of Medicine, pp. 22-28, (1984)
[15]  
Frederickson, Wilcox, Bucci, Loon, Peterson, Brown, Thompson, Smith, Wingo, A Prospective Evaluation of a Simplified Captopril Test for the Detection of Renovascular Hypertension, Archives of Internal Medicine, 150, pp. 567-572, (1990)
[16]  
Thibonnier, Joseph, Sassano, Guyenne, Corvol, Raynaud, Seurot, Gaux, Improved diagnosis of unilateral renal artery lesions after Captopril administration, JAMA, 251, pp. 56-60, (1984)
[17]  
Meier, Sumpio, Black, Gusberg, Captopril renal scintigraphy-an advance in detection and treatment of renovascular hypertension, J Vase Surg, 11, pp. 770-777, (1990)
[18]  
Geyskes, De Bruyn, Captopril Renography and the Effect of Percutaneous Transluminal Angioplasty on Blood Pressure in 94 Patients With Renal Artery Stenosis, American Journal of Hypertension, 41, pp. 685-689, (1991)
[19]  
Fommei, Mezzasalma, Ghione, Volterrani, Oei, Hilson, Carrieri, Preliminary results. Inspective renographic analysis, The European Catopril Radionuclide Tests Multicenter Study Group, 41, pp. 690-697, (1991)
[20]  
Sfakianakis, Bourgoignic, Jaffe, Kyriakides, Perezstable, Duncan, Single-dose captopril scintigraphy in the diagnosis of renovascular hypertension, J Nuc Med, 28, pp. 1383-1392, (1987)