ELECTRON-CYCLOTRON-RESONANCE PLASMA REACTOR FOR CRYOGENIC ETCHING

被引:20
作者
AYDIL, ES
GREGUS, JA
GOTTSCHO, RA
机构
[1] AT and T Bell Laboratories, Murray Hill, NJ 07974
关键词
D O I
10.1063/1.1144284
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electron cyclotron resonance (ECR) plasma reactors are being used for ultralarge scale integrated circuit fabrication to meet the stringent requirements on submicron feature etching. Three issues are critical for ECR reactor design: plasma uniformity, ion energy control, and wafer temperature control. Plasma uniformity is important for minimizing over etch times and reducing the probability of producing charging damage. Ion energy control is needed to optimize etching rate, anisotropy, and selectivity without compromising device yield. Wafer temperature control is important because large ion currents at low pressure can result in wafer heating and thereby alter the rates of surface chemical processes. An ECR plasma reactor is described that is designed to etch compound semiconductors and Si at low temperatures (-170 to 20-degrees-C), where superior selectivity and linewidth control are achievable. By measuring dc bias, floating potential, and ion saturation current densities it is shown that ion energies in this system can be control led by applying an rf bias to the sample. To characterize plasma uniformity, the radial ion density profile is measured using a fast injection Langmuir probe. Hollow, peaked, or uniform radial plasma density profiles can be obtained depending on microwave power, pressure, and magnetic field. Plasma density profiles are influenced by microwave absorption and refraction which, in turn, are influenced by both the magnetic field and plasma density profiles. The net result is a strong coupling between wave propagation and charge particle transport. To control wafer temperature a cryogenic electrode capable of maintaining a wafer temperature to +/-2.5-degrees-C at -170-degrees-C is used while the wafer is exposed to an electron cyclotron resonance plasma. The sample temperature is monitored using infrared laser interferometric thermometry and the heat flux to the wafer surface in an Ar plasma is measured as a function of operating parameters by monitoring temperature transients as the discharge is gated on and off.
引用
收藏
页码:3572 / 3584
页数:13
相关论文
共 56 条
  • [1] ELECTRON-CYCLOTRON RESONANCE MICROWAVE DISCHARGES FOR ETCHING AND THIN-FILM DEPOSITION
    ASMUSSEN, J
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1989, 7 (03): : 883 - 893
  • [2] MODELING OF PLASMA-ETCHING REACTORS INCLUDING WAFER HEATING EFFECTS
    AYDIL, ES
    ECONOMOU, DJ
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (05) : 1471 - 1481
  • [3] AYDIL ES, IN PRESS J VAC SCI A
  • [4] Bers A., 1963, WAVES ANISOTROPIC PL
  • [5] Bohm D, 1949, CHARACTERISTICS ELEC
  • [6] BOWDEN M, UNPUB
  • [7] AXIAL RADIO-FREQUENCY ELECTRIC-FIELD INTENSITY AND ION DENSITY DURING LOW TO HIGH MODE TRANSITION IN ARGON ELECTRON-CYCLOTRON RESONANCE DISCHARGES
    CARL, DA
    WILLIAMSON, MC
    LIEBERMAN, MA
    LICHTENBERG, AJ
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1991, 9 (02): : 339 - 347
  • [8] Chen F F, 1965, PLASMA DIAGNOSTIC TE
  • [9] ELECTRON-CYCLOTRON RESONANCE PLASMA-ETCHING USING DOWNSTREAM MAGNETIC CONFINEMENT
    CHOQUETTE, KD
    WETZEL, RC
    FREUND, RS
    KOPF, RF
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (06): : 2725 - 2728
  • [10] COOK JM, 1991, SOLID STATE TECHNOL, V34, P119