DETERMINATION OF TRACES OF COPPER, CADMIUM AND LEAD IN BIOLOGICAL AND ENVIRONMENTAL-SAMPLES BY FLOW-INJECTION ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:30
作者
LU, PL [1 ]
HUANG, KS [1 ]
JIANG, SJ [1 ]
机构
[1] NATL SUN YAT SEN UNIV,DEPT CHEM,KAOHSIUNG 804,TAIWAN
关键词
FLOW INJECTION; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; ISOTOPE DILUTION METHODS; BIOLOGICAL SAMPLES; CADMIUM; COPPER; ENVIRONMENTAL ANALYSIS; LEAD;
D O I
10.1016/0003-2670(93)80022-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow-injection isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) was applied to the determination of Cu, Cd and Pb in several biological and environmental reference materials. The isotope ratios for each injection were calculated from the areas of the flow-injection peaks. The precision for the isotope ratio determination was better than 1%. Detection limits were 45, 25 and 58 ng l(-1) for Cu, Cd, and Pb, respectively. The flow-injection isotope dilution method was successfully applied to the determination of Cu, Cd and Pb in a urine reference sample (NIST SRM 2670). A preconcentration system was used for the separation of Na and Mg matrix elements and preconcentration of traces of Cu, Cd and Pb in SLRS-2 riverine water and CASS-2 open ocean sea-water reference samples.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 32 条
[1]   DETERMINATION OF TRACE-METALS IN AN OPEN OCEAN WATER REFERENCE MATERIAL BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
MYKYTIUK, AP ;
BERMAN, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :305-308
[2]   DETERMINATION OF TRACE-METALS IN A RIVER WATER REFERENCE MATERIAL BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
MYKYTIUK, AP ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :778-783
[3]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[4]   THE INFLUENCE OF POLYATOMIC ION INTERFERENCES IN ANALYSIS BY INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY (ICP-MS) [J].
DATE, AR ;
CHEUNG, YY ;
STUART, ME .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :3-20
[5]   SELECTION OF MODE FOR THE MEASUREMENT OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ITS APPLICATION TO MILK POWDER ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
MASSEY, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) :369-374
[6]   STUDY OF SOLIDS DEPOSITION ON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SAMPLERS AND SKIMMERS [J].
DOUGLAS, DJ ;
KERR, LA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :749-752
[7]  
DOUGLAS DJ, 1985, PROG ANAL ATOM SPECT, V8, P1
[8]   STABLE ISOTOPE-DILUTION ANALYSIS OF HYDROLOGIC SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GARBARINO, JR ;
TAYLOR, HE .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1568-1575
[10]   MINIMIZATION OF INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING ONLINE PRECONCENTRATION [J].
HEITHMAR, EM ;
HINNERS, TA ;
ROWAN, JT ;
RIVIELLO, JM .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :857-864