SAFETY AND EFFICACY OF KIDNEY-TRANSPLANT BIOPSY - TRU-CUT NEEDLE VS SONOGRAPHICALLY GUIDED BIOPTY GUN

被引:57
作者
MAHONEY, MC
RACADIO, JM
MERHAR, GL
FIRST, MR
机构
[1] UNIV HOSP CINCINNATI,DEPT NEPHROL,CINCINNATI,OH 45267
[2] UNIV CINCINNATI,SCH MED,CINCINNATI,OH 45267
关键词
D O I
10.2214/ajr.160.2.8424343
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We evaluated the safety and efficacy of using a 14-gauge Tru-Cul needle without imaging guidance vs using an 18-gauge Biopty gun with sonographic guidance for percutaneous biopsy of kidney transplants. MATERIALS AND METHODS. We retrospectively analyzed data from 105 biopsies (in 68 patients) in which the Biopty gun with an 18-gauge needle was used and data from 100 biopsies (in 64 patients) in which a 14-gauge Tru-Cut needle was used. RESULTS. Significantly fewer major complications (p = .03) occurred when the Biopty gun was used (2%) vs when the Tru-Cut needle was used (10%). Two major complications (2%), both hematuria requiring transfusion, occurred in the 105 biopsies performed with the Biopty gun. Major complications occurred in 10 (10%) of the 100 biopsies done with the Tru-Cut needle: three obstructed allografts caused by blood clots, two episodes of hypovolemic shock, one case of shock and obstruction, and four intraperitoneal hemorrhages (one of which required nephrectomy). Biopsy specimens were adequate for histopathologic diagnosis in more than 98% of cases for both the Biopty gun and the Tru-Cut needle. CONCLUSION. We conclude that imaging-guided percutaneous biopsy of renal allografts with a Biopty gun is as accurate as and safer than biopsy with the Tru-Cut needle.
引用
收藏
页码:325 / 326
页数:2
相关论文
共 6 条
[1]   MINICORE NEEDLE-BIOPSY OF KIDNEY-TRANSPLANTS - A SAFER SAMPLING METHOD [J].
BELITSKY, P ;
GUPTA, R .
JOURNAL OF UROLOGY, 1990, 144 (02) :310-311
[2]   NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES [J].
BOGAN, ML ;
KOPECKY, KK ;
KRAFT, JL ;
HOLLADAY, AO ;
FILO, RS ;
LEAPMAN, SB ;
THOMALLA, JV .
RADIOLOGY, 1990, 174 (01) :273-275
[3]  
DIXON TK, 1991, CLIN TRANSPLANT, V5, P126
[4]   EFFECT OF NEEDLE GAUGE, LEVEL OF ANTICOAGULATION, AND TARGET ORGAN ON BLEEDING ASSOCIATED WITH ASPIRATION BIOPSY - WORK IN PROGRESS [J].
GAZELLE, GS ;
HAAGA, JR ;
ROWLAND, DY .
RADIOLOGY, 1992, 183 (02) :509-513
[5]   A NEW TECHNIQUE FOR RENAL-ALLOGRAFT BIOPSY [J].
UBHI, CS ;
IRVING, HC ;
GUILLOU, PJ ;
GILES, GR .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (714) :599-600
[6]   PERCUTANEOUS NEEDLE-BIOPSY OF THE RENAL-ALLOGRAFT - A CLINICAL SAFETY EVALUATION OF 1129 BIOPSIES [J].
WILCZEK, HE .
TRANSPLANTATION, 1990, 50 (05) :790-797