IMPEDANCE TO DEFIBRILLATION COUNTERSHOCK - DOES AN OPTIMAL IMPEDANCE EXIST

被引:17
作者
KENKNIGHT, BH
EYUBOGLU, BM
IDEKER, RE
机构
[1] UNIV ALABAMA,DEPT MED,BIRMINGHAM,AL 35294
[2] DUKE UNIV,ENGN RES CTR EMERGING CARDIOVASC TECHNOL,DURHAM,NC
[3] CARDIAC PACEMAKERS INC,DEPT THERAPY RES,ST PAUL,MN
[4] HACETTEPE UNIV,DEPT ELECT & ELECTR ENGN,ANKARA,TURKEY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 11期
关键词
DEFIBRILLATION; COUNTERSHOCK; IMPEDANCE; IMPLANTABLE DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1995.tb03869.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Defibrillation is thought to occur because of changes in the transmembrane potential that are caused by current flow through the heart tissue. Impedance to electric countershock is an important parameter because it is determined by She magnitude and distribution of the current that flows for a specific shock voltage, The impedance is comprised of resistive contributions from: (1) extra-tissue sources, which include the defibrillator, leads, and electrodes; (2) tissue sources, which include intracardiac and extracardiac tissue; and (3) the interface between electrode and tissue, Tissue sources dominate the impedance and probably contribute to the wide range of impedance values presented to the defibrillation pulse. Because impedance is not constant within or between subjects, defibrillators must be designed to accommodate these differences without compromising patient safety or therapeutic efficacy. Experimental investigations in animals and humans suggest that impedance changes at several different time scales ranging from milliseconds to years. These alterations are believed to be a result of both electrochemical and physiological mechanisms. It is commonly thought that impedance is optimized when it hers been decreased to a minimum, since this allows the most current flow for a given voltage shock. However er, if the impedance is lowered by changing the location or size of the electrodes in such a way that current flow is decreased in part of the heart even though current flow is increased elsewhere, then the total voltage, current, and energy needed for defibrillation may increase, not decrease, even though impedance is decreased. A simple boundary element computer model suggests that the most even distribution of current flow through the heart is achieved for those electrode locations in which the impedance across the heart is at or near the maximum cardiac impedance for any location of these particular electrodes, Thus, the optimum shock impedance is achieved when impedance is minimized for extra-tissue ansi extra-cardiac tissue sources and is at or near a maximum for intracardiac tissue sources.
引用
收藏
页码:2068 / 2087
页数:20
相关论文
共 141 条
[71]   ADVANCE PREDICTION OF TRANS-THORACIC IMPEDANCE IN HUMAN DEFIBRILLATION AND CARDIOVERSION - IMPORTANCE OF IMPEDANCE IN DETERMINING THE SUCCESS OF LOW-ENERGY SHOCKS [J].
KERBER, RE ;
KOUBA, C ;
MARTINS, J ;
KELLY, K ;
LOW, R ;
HOYT, R ;
FERGUSON, D ;
BAILEY, L ;
BENNETT, P ;
CHARBONNIER, F .
CIRCULATION, 1984, 70 (02) :303-308
[72]   DETERMINANTS OF DEFIBRILLATION - PROSPECTIVE ANALYSIS OF 183 PATIENTS [J].
KERBER, RE ;
JENSEN, SR ;
GASCHO, JA ;
GRAYZEL, J ;
HOYT, R ;
KENNEDY, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (07) :739-745
[73]   OPTIMAL ELECTRODE DESIGNS FOR ELECTROSURGERY, DEFIBRILLATION, AND EXTERNAL CARDIAC PACING [J].
KIM, Y ;
BENFAHY, J ;
TUPPER, BJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (09) :845-853
[74]   OPTICAL RECORDINGS OF THE EFFECT OF ELECTRICAL-STIMULATION ON ACTION-POTENTIAL REPOLARIZATION AND THE INDUCTION OF REENTRY IN 2-DIMENSIONAL PERFUSED RABBIT EPICARDIUM [J].
KNISLEY, SB ;
HILL, BC .
CIRCULATION, 1993, 88 (05) :2402-2414
[75]   POTENTIAL DISTRIBUTION IN 3-DIMENSIONAL PERIODIC MYOCARDIUM .1. SOLUTION WITH 2-SCALE ASYMPTOTIC ANALYSIS [J].
KRASSOWSKA, W ;
PILKINGTON, TC ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :252-266
[76]  
KRASSOWSKA W, 1988, PACE, V11, P509
[77]   PERIODIC CONDUCTIVITY AS A MECHANISM FOR CARDIAC STIMULATION AND DEFIBRILLATION [J].
KRASSOWSKA, W ;
PILKINGTON, TC ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (07) :555-560
[78]  
Krassowska W., 1992, Proceedings of Computer in Cardiology 1992 (Cat. No.92CH3259-9), P703, DOI 10.1109/CIC.1992.269336
[79]  
KUGELBERG J, 1972, Scandinavian Journal of Thoracic and Cardiovascular Surgery, V6, P274, DOI 10.3109/14017437209134810
[80]  
LANG DJ, 1994, IMPLANTABLE CARDIOVE, P223