PANORAMIC INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS OF SYNTHETIC AND NATURAL SILICA - A PERFORMANCE REVIEW OF THE K0 STANDARDIZATION METHOD

被引:14
作者
DECORTE, F [1 ]
DEWISPELAERE, A [1 ]
VANDENBOER, M [1 ]
BOSSUS, D [1 ]
VANSLUIJS, R [1 ]
机构
[1] DSM RES & PATENTS,6160 MD GELEEN,NETHERLANDS
关键词
ATOMIC ABSORPTION SPECTROMETRY; SILICA; STANDARDIZATION;
D O I
10.1016/0003-2670(91)90019-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on the k0 standardization method, a panoramic instrumental neutron activation analysis was applied to synthetic and natural silica samples and concentrations and/or detection limits were obtained for 58 elements. The Si content, expected to be ca. 46.7% by weight, was also determined as a criterion for the absence of gross errors. From the results, conclusions were drawn regarding desirable extensions and improvements to the k0 method, such as the further determination and recommendation of k0 factors (e.g., for Ge and Te isotopes), and the elaboration of procedures allowing the introduction of "non-1/upsilon" radionuclides [e.g. Eu-152(m); requiring the introduction of the Westcott convention and of neutron temperature monitoring] and of low-energy gamma-emitters (e.g., some rare earth elements; requiring counting on an LEPD).
引用
收藏
页码:127 / 143
页数:17
相关论文
共 23 条
[1]   MICROSAMPO - PERSONAL-COMPUTER BASED ADVANCED GAMMA-SPECTRUM ANALYSIS SYSTEM [J].
AARNIO, PA ;
ROUTTI, JT ;
SANDBERG, JV .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1988, 124 (02) :457-466
[2]   DEAD-TIME CORRECTION SYSTEM FOR GAMMA-RAY SPECTROMETRY OF SHORT-LIVED ISOTOPES [J].
BARTOSEK, J ;
ADAMS, F ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (01) :45-&
[4]  
DEBEECK JO, 1976, DESCRIPTION STRUCTUR
[5]   KO-MEASUREMENTS AND RELATED NUCLEAR-DATA COMPILATION FOR (N,GAMMA) REACTOR NEUTRON-ACTIVATION ANALYSIS [J].
DECORTE, F ;
SIMONITS, A ;
DEWISPELAERE, A ;
ELEK, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1989, 133 (01) :3-41
[6]  
DECORTE F, 1989, J RADIOAN NUCL CH AR, V133, P43, DOI 10.1007/BF02039970
[7]   ACCURACY AND APPLICABILITY OF THE K0-STANDARDIZATION METHOD [J].
DECORTE, F ;
SIMONITS, A ;
DEWISPELAERE, A ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 113 (01) :145-161
[8]   THE CALIBRATION OF A LOW-ENERGY PHOTON GERMANIUM DETECTOR FOR USE IN THE NAA K0 STANDARDIZATION METHOD [J].
DECORTE, F ;
FREITAS, MC ;
DEWISPELAERE, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3) :335-343
[9]   APPLICABILITY OF THE 1/E1+ALPHA-EPITHERMAL SPECTRUM REPRESENTATION AND THE EFFECTIVE RESONANCE ENERGY ER IN NAA [J].
DECORTE, F ;
MOENS, L ;
JOVANOVIC, S ;
SIMONITS, A ;
DEWISPELAERE, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1986, 102 (01) :37-57
[10]   SOME STANDARDIZATION PROBLEMS IN REACTOR NEUTRON-ACTIVATION ANALYSIS [J].
DECORTE, F ;
HOSTE, J .
ISOTOPENPRAXIS, 1989, 25 (07) :269-273