VALUE OF NOTCHING AND SLURRING OF THE RESTING QRS COMPLEX IN THE DETECTION OF ISCHEMIC-HEART-DISEASE

被引:13
作者
FRANCE, RJ
FORMOLO, JM
PENNEY, DG
机构
[1] WAYNE STATE UNIV, SCH MED, DEPT PHYSIOL, 540 E CANFIELD, DETROIT, MI 48201 USA
[2] ST JOHNS HOSP, DEPT MED, DETROIT, MI USA
关键词
coronary artery disease; ischemic heart disease; myocardial infarction; Q waves; QRS notching and slurring; ventricular wall motion;
D O I
10.1002/clc.4960130309
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The resting 12‐lead ECG has long been known to be an insensitive marker of underlying ischemic heart disease (IHD). The purpose of this study was to determine if QRS complex notching and slurring is of significant value as a diagnostic discriminator in the detection of IHD. The data from 205 consecutive patients coming to cardiac catheterization for evaluation of probable IHD were initially analyzed. Eighty‐three patients were excluded based upon ventricular hypertrophy, bundle‐branch block, lack of data, and pacemaker rhythm. The balance, 122 patients (mean age 61.7 years), were evaluated for angiographic evidence of IHD, ECG findings of QRS notching or slurring, and abnormal Q waves. The data revealed a high prevalence of QRS notching or slurring; 62.2% in those patients with IHD, double the prevalence of significant Q waves (33.3%). The two markers had an approximately equal prevalence (QRS notching or slurring 61.7% vs. Q waves 53.2%) in patients with angiographic evidence of infarction; however, in patients with less than infarct criteria for IHD, the prevalence of QRS notching or slurring was 62.8%, while only 11.6% showed abnormal Q waves. Analysis indicated that QRS notching or slurring has a sensitivity of 62.2% and a specificity of 93.8% for the detection of IHD. The study demonstrates that QRS notching or slurring is a moderately sensitive and a very specific marker of ischemic heart disease in selected patients when using the resting ECG, and is of greatest value in those patients with lesser degrees of ischemic myocardial injury where the prevalence of Q waves is low. Copyright © 1990 Wiley Periodicals, Inc.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 44 条
[21]   ELECTROCARDIOGRAPHIC CRITERIA FOR VENTRICULAR-TACHYCARDIA IN WIDE COMPLEX LEFT-BUNDLE BRANCH-BLOCK MORPHOLOGY TACHYCARDIAS [J].
KINDWALL, KE ;
BROWN, J ;
JOSEPHSON, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1279-1283
[22]   PREDICTIVE ACCURACY OF CRITERIA FOR CHRONIC MYOCARDIAL-INFARCTION IN PACING-INDUCED LEFT-BUNDLE BRANCH-BLOCK [J].
KINDWALL, KE ;
BROWN, JP ;
JOSEPHSON, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (15) :1255-1260
[23]   WIDE BAND RECORDING OF ELECTROCARDIOGRAM AND CORONARY HEART-DISEASE [J].
LANGNER, PH ;
GESELOWITZ, DB ;
BRILLER, SA .
AMERICAN HEART JOURNAL, 1973, 86 (03) :308-317
[24]   HIGH-FIDELITY ELECTROCARDIOGRAPHY - EFFECTS OF INDUCED LOCALIZED MYOCARDIAL INJURY IN DOG [J].
LANGNER, PH ;
DEMOTT, T ;
HUSSEY, M .
AMERICAN HEART JOURNAL, 1966, 71 (06) :790-&
[25]   CLINICAL CORRELATION OF CORONARY ARTERIOGRAPHY [J].
LIKOFF, W ;
KASPARIA.H ;
SEGAL, BL ;
NOVACK, P ;
LEHMAN, JS .
AMERICAN JOURNAL OF CARDIOLOGY, 1965, 16 (02) :159-&
[26]   NORMAL ELECTROCARDIOGRAM IN PRESENCE OF SEVERE CORONARY ARTERY DOSEASE [J].
MARTINEZRIOS, MA ;
BRUTODAC.B ;
CECENASE.F ;
GENSINI, GG .
AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (03) :320-+
[27]   THE ELECTROCARDIOGRAPHIC DIAGNOSIS OF RIGHT VENTRICULAR HYPERTROPHY [J].
MYERS, GB ;
KLEIN, HA ;
STOFER, BE .
AMERICAN HEART JOURNAL, 1948, 35 (01) :1-40
[28]   CORRELATION OF ELECTROCARDIOGRAPHIC AND PATHOLOGIC FINDINGS IN ANTEROSEPTAL INFARCTION .1. [J].
MYERS, GB ;
KLEIN, HA ;
STOFER, BE .
AMERICAN HEART JOURNAL, 1948, 36 (04) :535-575
[29]   CORRELATION OF ELECTROCARDIOGRAPHIC AND PATHOLOGIC FINDINGS IN ANTEROPOSTERIOR INFARCTION .3. [J].
MYERS, GB ;
KLEIN, HA ;
HIRATZKA, T .
AMERICAN HEART JOURNAL, 1949, 37 (02) :205-236
[30]   CORRELATION OF ELECTROCARDIOGRAPHIC AND PATHOLOGIC FINDINGS IN LARGE ANTEROLATERAL INFARCTS .2. [J].
MYERS, GB ;
KLEIN, HA ;
HIRATZKA, T .
AMERICAN HEART JOURNAL, 1948, 36 (06) :838-881