AUTOMATED QUASI-CONTINUOUS IMMUNOANALYSIS OF PESTICIDES WITH A FLOW-INJECTION SYSTEM

被引:19
作者
KRAMER, PM [1 ]
SCHMID, RD [1 ]
机构
[1] GESELL BIOTECHNOL FORSCH GMBH,DEPT ENZYME TECHNOL,W-3300 BRAUNSCHWEIG,GERMANY
来源
PESTICIDE SCIENCE | 1991年 / 32卷 / 04期
关键词
D O I
10.1002/ps.2780320407
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Chemical methods (HPLC, GC/MS) for the control of pesticides in water at low concentrations are time-consuming, expensive and need sample pre-concentration. Immunoassays offer the potential of rapid, inexpensive, sensitive and specific detection methods. This paper presents a flow injection system that is based on immunochemical reaction and which provides the opportunity for automated, quasi-continuous measurements for screening water samples for the presence of pesticides. The method of flow injection immunoanalysis (FIIA) was compared with competitive ELISA (enzyme-linked immunosorbent assay). It is possible to measure in the range of interest of 0.1-mu-g litre-1, which is the limiting value of the European drinking water directive. Measurements were made for the triazine herbicides atrazine and propazine, which both cross-react with the polyclonal antiserum used. Furthermore, this device includes a new development of a membrane reactor for the exchange of used biological material, in this case antibodies. A brief comparison of ELISA and FIIA is presented, giving an overview of some aspects of the assays.
引用
收藏
页码:451 / 462
页数:12
相关论文
共 18 条
[1]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[2]   AN AUTOMATIC AND STERILIZABLE SAMPLER FOR LABORATORY FERMENTERS - APPLICATION TO THE ONLINE CONTROL OF GLUCOSE-CONCENTRATION [J].
GHOUL, M ;
RONAT, E ;
ENGASSER, JM .
BIOTECHNOLOGY AND BIOENGINEERING, 1986, 28 (01) :119-121
[3]  
Goodson L H, 1976, Methods Enzymol, V44, P647
[4]  
HABERER K, 1988, WASSER, V71, P231
[5]  
Hammock B. D., 1987, Pesticide science and biotechnology. Proceedings of the 6th international congress of pesticide chemistry held in Ottawa, Canada, 10-15 Aug. 1986, P309
[6]  
HOCK B, 1989, Z WASSER ABWASS FOR, V22, P78
[7]   USE OF IMMUNOCHEMICAL TECHNIQUES FOR THE ANALYSIS OF PESTICIDES [J].
JUNG, F ;
GEE, SJ ;
HARRISON, RO ;
GOODROW, MH ;
KARU, AE ;
BRAUN, AL ;
LI, QX ;
HAMMOCK, BD .
PESTICIDE SCIENCE, 1989, 26 (03) :303-317
[8]   EXCHANGEABLE IMMOBILIZED ENZYME REACTOR FOR ENZYME-INHIBITION TESTS IN FLOW-INJECTION ANALYSIS USING A MAGNETIC DEVICE - DETERMINATION OF PESTICIDES IN DRINKING-WATER [J].
KINDERVATER, R ;
KUNNECKE, W ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :113-117
[9]   FLOW-INJECTION IMMUNOANALYSIS (FIIA) - A NEW IMMUNOASSAY FORMAT FOR THE DETERMINATION OF PESTICIDES IN WATER [J].
KRAMER, P ;
SCHMID, R .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :239-243
[10]  
KRAMER P, 1990, VOM WASSER, V75, P99