USE OF HEAT AND MOISTURE EXCHANGING (HME) FILTERS IN MECHANICALLY VENTILATED ICU PATIENTS - INFLUENCE ON AIRWAY FLOW-RESISTANCE

被引:30
作者
CHIARANDA, M
VERONA, L
PINAMONTI, O
DOMINIONI, L
MINOJA, G
CONTI, G
机构
[1] UNIV PAVIA, DEPT SURG ANAESTHESIOL & INTENS CARE, VARESE, ITALY
[2] UNIV ROMA LA SAPIENZA, INST ANAESTHESIOL & INTENS CARE, ROME, ITALY
关键词
HEAT; HUMIDITY; RESPIRATION; ARTIFICIAL INSTRUMENTATION; HME;
D O I
10.1007/BF01711088
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To investigate the flow-resistance of a new generation of Heat Moisture Exchanging Filters (HME filters) during 24 h of clinical use. Design: Before-after trial. Setting: A general Intensive Care Unit of a university hospital. Patients: A consecutive series of 96 patients undergoing mechanical ventilation for respiratory insufficiency of various etiology and severity. Methods: The characteristics of the secretions collected by tracheal suctioning and the pressure/flow relationship of the HMEs before and after 24 h of clinical use were analyzed. Results: The resistance of the HMEs when dry was 2 hPa/l.s, and it increased to a maximum of 1 hPa/l.s in 83% of the patients after 24 hours; in four patients with particularly heavy secretions HME resistance was 4-5 hPa/l.s. There were no significant modifications of the secretions within the investigation period, excluding, in particular, an increase in density with consequent tracheal tube obstruction. Conclusion: The gas conditioning efficiency and design performance of the tested HMEs did not create a significant obstacle to airflow medium term mechanical ventilation; however, these devices should be cautiously used in patients with heavy bronchial secretions.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 36 条
[11]  
CONTI G, 1992, Acta Anaesthesiologica Italica, V43, P81
[12]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[13]   TEMPERATURE, HUMIDITY AND MUCUS FLOW IN INTUBATED TRACHEA [J].
FORBES, AR .
BRITISH JOURNAL OF ANAESTHESIA, 1974, 46 (01) :29-34
[14]   CONTAMINATION CONTROL IN LONG-TERM VENTILATION - A CLINICAL-STUDY USING A HEAT-EXCHANGING AND MOISTURE-EXCHANGING FILTER [J].
GALLAGHER, J ;
STRANGEWAYS, JEM ;
ALLTGRAHAM, J .
ANAESTHESIA, 1987, 42 (05) :476-481
[15]  
GRAFF TD, 1975, ANESTH ANALG, V54, P444
[16]   REACTIONS TO AEROSOL MEDICATION IN INFANTS AND CHILDREN [J].
HARRIS, RL ;
RILEY, HD .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 201 (12) :953-&
[17]   EVALUATION OF BACTERIAL CONTAMINATION OF VENTILATOR HUMIDIFYING SYSTEMS [J].
HARRIS, TM ;
RAMAN, TK ;
RICHARDS, WJ ;
COVERT, SV ;
BLAKE, JA ;
ACCURSO, J .
CHEST, 1973, 63 (06) :922-925
[18]  
JACKSON C, 1992, Acta Anaesthesiologica Italica, V43, P77
[19]   AN UNEXPECTED COMPLICATION (HYPERTHERMIA) WHILE USING EMERSON POSTOPERATIVE VENTILATOR [J].
KIRCH, TJ ;
DEKORNFE.TJ .
ANESTHESIOLOGY, 1967, 28 (6P1) :1106-&
[20]   HOT-POT TRACHEITIS [J].
KLEIN, EF ;
GRAVES, SA .
CHEST, 1974, 65 (02) :225-226