MODELING THE EFFECT OF FLOW HETEROGENEITY ON CORONARY PERMEABILITY-SURFACE AREA

被引:21
作者
OVERHOLSER, KA
BHATTE, MJ
LAUGHLIN, MH
机构
[1] UNIV MISSOURI,DEPT VET BIOMED SCI,COLUMBIA,MO 65211
[2] UNIV MISSOURI,DALTON RES CTR,COLUMBIA,MO 65211
[3] UNIV MISSOURI,DEPT MED PHYSIOL,COLUMBIA,MO 65211
关键词
CORONARY BLOOD FLOW; PERMEABILITY-SURFACE AREA PRODUCT; CAPILLARY TRANSPORT; MICROSPHERES;
D O I
10.1152/jappl.1991.71.2.758
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In 11 anesthetized pigs, the left anterior descending coronary artery (LAD) was cannulated and pump perfused with blood before and during maximum adenosine vasodilation. For LAD plasma flows (F) ranging from 0.42 to 3.6 ml.min-1.g perfused tissue-1, we injected radiolabeled microspheres to measure heterogeneity and used the multiple indicator-dilution method to measure permeability-surface area product (PS) for EDTA. Heterogeneity of flow from the LAD was expressed as relative dispersion (RD) = standard deviation of flow/mean flow. Values of RD, corrected for tissue sample size using fractal theory, ranged from 13 to 87%, approaching 16-35% at high F. We developed a "variable-recruitment model" of regional heterogeneous capillary transport to correct PS for flow heterogeneity and capillary surface area recruitment. Values of PS ranged from 0.14 to 0.96 ml.min-1.g-1. Accounting for heterogeneity increased PS values by 0-18% compared with homogeneous values. Results revealed PS to be proportional to flow up to F = 1.5-2.1 ml.min-1.g-1 and then was constant at higher flows. The initial increase of PS with F may be due to capillary recruitment. When full recruitment is reached, PS becomes independent of F. We conclude that flow heterogeneity is significant but not readily predictable in the pig myocardium and that the use of microspheres to correct indicator-dilution data for flow heterogeneity improves the interpretation of multiple-tracer studies, particularly when tracers are used to study interventions that may alter flow distribution.
引用
收藏
页码:758 / 769
页数:12
相关论文
共 28 条
[11]   CONCURRENT INCREASES IN RESISTANCE AND TRANSPORT AFTER CORONARY OBSTRUCTION IN DOGS [J].
HARRIS, TR ;
OVERHOLSER, KA ;
STILES, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (02) :H262-H273
[12]   STABILITY OF HETEROGENEITY OF MYOCARDIAL BLOOD-FLOW IN NORMAL AWAKE BABOONS [J].
KING, RB ;
BASSINGTHWAIGHTE, JB ;
HALES, JRS ;
ROWELL, LB .
CIRCULATION RESEARCH, 1985, 57 (02) :285-295
[13]   MULTIPLE TRACER DILUTION ESTIMATES OF D AND 2-DEOXY-D-GLUCOSE UPTAKE BY THE HEART [J].
KUIKKA, J ;
LEVIN, M ;
BASSINGTHWAIGHTE, JB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (01) :H29-H42
[14]   CORONARY TRANSPORT RESERVE IN NORMAL DOGS [J].
LAUGHLIN, MH .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) :551-561
[15]   CORONARY BLOOD-FLOW RESERVE DURING +GZ STRESS AND TREADMILL EXERCISE IN MINIATURE SWINE [J].
LAUGHLIN, MH ;
BURNS, JW ;
FANTON, J ;
RIPPERGER, J ;
PETERSON, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (06) :2589-2596
[16]   MYOCARDIAL CAPILLARITY AND MAXIMAL CAPILLARY DIFFUSION CAPACITY IN EXERCISE-TRAINED DOGS [J].
LAUGHLIN, MH ;
TOMANEK, RJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (04) :1481-1486
[17]   VASCULAR TRANSPORT CAPACITY OF HINDLIMB MUSCLES OF EXERCISE-TRAINED RATS [J].
LAUGHLIN, MH ;
RIPPERGER, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (02) :438-443
[18]   MYOCARDIAL TRANSCAPILLARY EXCHANGE IN HYPERTROPHIED HEART OF DOG [J].
LAUGHLIN, MH ;
DIANA, JN .
AMERICAN JOURNAL OF PHYSIOLOGY, 1975, 229 (03) :838-846
[19]   EXERCISE TRAINING INCREASES CORONARY TRANSPORT RESERVE IN MINIATURE SWINE [J].
LAUGHLIN, MH ;
OVERHOLSER, KA ;
BHATTE, MJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (03) :1140-1149
[20]   EFFECTS OF EXERCISE TRAINING ON CORONARY TRANSPORT CAPACITY [J].
LAUGHLIN, MH .