ASSESSMENT OF BLOOD SUBSTITUTES .1. EFFICACY STUDIES IN ANESTHETIZED AND CONSCIOUS RATS WITH LOSS OF 1/3, 1/2 AND 2/3 BLOOD-VOLUME

被引:7
作者
CHANG, TMS
VARMA, R
机构
[1] Artificial Cells, Organs Research Centre, Faculty of Medicine, McGill University, Montreal, PQ
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY | 1994年 / 22卷 / 02期
基金
英国医学研究理事会;
关键词
D O I
10.3109/10731199409117411
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Acute and long-term recovery (14 days) studies were conducted in conscious rats bled 1/3, 1/2, and 2/3 blood volume, and in anesthetized rats bled 1/3 volume. Study I : bled lm blood volume. Study Ia : Anesthetized rats bled 1/3 blood volume were in shock and most died within 1 hour; the group which received infusion of 3x volume Ringer's lactate regained blood pressure with 100% long-term recovery. Study Ib: In conscious rats bled 1/3 blood volume, blood pressure did not fall to shock levels, and the long-term recovery in both the control group and the group which received 3x volume Ringer's lactate was 100%. Study II: Bled 1/2 blood volume. In conscious rats bled 1/2 volume, the blood pressure of the control group was slightly above 70mm Hg. Infusion of 3x volume Ringer's lactate or 7 gm% human albumin in Ringer's lactate increased blood pressure to above 90mmHg in the acute study. Long-term recovery and survival rate was 80% in both the controls and the Ringer's lactate group, and 100% in the albumin group. Study III: bled 2/3 blood volume. In conscious animals, loss of 2/3 blood volume resulted in fall of blood pressure to shock levels and death of the animal within 1 hour. Infusion of 3x volume Ringer's lactate did not increase blood pressure to above shock level. Stroma-free hemoglobin and polyhemoglobin increased blood pressure, and whole blood returned blood pressure to normal. In long-term recovery, poly-hemoglobin, but not SFHb, was as effective as whole blood with 100% long term recovery. Animal models in Study I and II are suitable only for studies of volume replacement. Animal models in Study III, especially using long-term recovery studies, are more suitable for studying both volume and red blood cells replacements.
引用
收藏
页码:159 / 169
页数:11
相关论文
共 10 条
[1]  
CHANG TMS, 1992, J BIOMATERIALS ARTIF, V20, P433
[2]   DEHYDRATION AND SHOCK - AN ANIMAL-MODEL OF HEMORRHAGE AND RESUSCITATION OF BATTLEFIELD INJURY [J].
HESS, JR ;
MACDONALD, VW ;
WINSLOW, RM .
BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1992, 20 (2-4) :499-502
[3]  
KEIPERT PE, 1985, BIOMATER ARTIF CELL, V13, P1
[4]   DIASPIRIN CROSS-LINKED HEMOGLOBIN SOLUTION AS A RESUSCITATIVE FLUID FOLLOWING SEVERE HEMORRHAGE IN THE RAT [J].
MALCOLM, D ;
KISSINGER, D ;
GARRIOCH, M .
BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1992, 20 (2-4) :495-497
[5]   PROSPECTIVE EVALUATION OF PREOPERATIVE FLUID RESUSCITATION IN HYPOTENSIVE PATIENTS WITH PENETRATING TRUNCAL INJURY - A PRELIMINARY-REPORT [J].
MARTIN, RR ;
BICKELL, WH ;
PEPE, PE ;
BURCH, JM ;
MATTOX, KL .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1992, 33 (03) :354-362
[6]  
MESSMER K, 1988, BLOOD SUBSTITUTES PR, P51
[7]   PEG-BOVINE HEMOGLOBIN - SAFETY IN A CANINE DEHYDRATED HYPOVOLEMIC-HEMORRHAGIC SHOCK MODEL [J].
NHO, K ;
GLOWER, D ;
BREDEHOEFT, S ;
SHANKAR, H ;
SHORR, R ;
ABUCHOWSKI, A .
BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1992, 20 (2-4) :511-524
[8]   RESUSCITATION OF BLED DOGS WITH PYRIDOXALATED-POLYMERIZED HEMOGLOBIN SOLUTION [J].
NING, J ;
ANDERSON, PJ ;
BIRO, GP .
BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1992, 20 (2-4) :525-530
[9]   INTERMITTENT VASCULAR ACCESS FOR EXTRACORPOREAL-CIRCULATION IN CONSCIOUS RATS - A NEW TECHNIQUE [J].
TABATA, Y ;
CHANG, TMS .
ARTIFICIAL ORGANS, 1982, 6 (02) :213-215
[10]  
WIGGERS CJ, 1950, PHYSL SHOCK, P138