DETERMINATION OF BETA-2-RECEPTOR AGONISTS IN BOVINE URINE AND LIVER BY GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY

被引:70
作者
LEYSSENS, L
DRIESSEN, C
JACOBS, A
CZECH, J
RAUS, J
机构
[1] Dr. L. Willems-Instituut, B-3610 Diepenbeek, Universitaire Campus
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 564卷 / 02期
关键词
D O I
10.1016/0378-4347(91)80520-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly specific and sensitive method for the simultaneous detection of seven beta-2-receptor agonists in bovine liver homogenates and urine was developed. A 10-g amount of liver was homogenized and treated with Subtilisin A(R). The resulting enzymatic digest was extracted with tert.-butanol-ethyl acetate (3:7) and the crude extract was purified on a 6-ml Bakerbond(R) alumina neutral disposable extraction column. Subsequently, the hydrous eluate from the alumina column was buffered at pH 6 and loaded on top of a preconditioned 3-ml Bond-Elut Certify(R) column. Urine was buffered and loaded onto a 3-ml Certify column without pretreatment. The analytes were eluted with dichloromethane-isopropanol (8:2) containing 2% ammonia. The extract obtained was trimethylsilylated and analysed by gas chromatography-tandem mass spectrometry using multiple selected reaction monitoring. The limits of detection for the beta-2-receptor agonists evaluated were between 0.5 and 5 ppb.
引用
收藏
页码:515 / 527
页数:13
相关论文
共 30 条
[1]   A RAPID SCREENING-PROCEDURE FOR THE DETECTION AND QUANTIFICATION OF CLENBUTEROL IN BOVINE URINE USING THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLANCHFLOWER, WJ ;
KENNEDY, DG .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (10) :935-936
[2]   ION-PAIR EXTRACTION OF SOME SYMPATHOMIMETICS - DESCRIPTION OF AN EXTRACTION MODEL FOR TERBUTALINE AND INVESTIGATION OF SOME FACTORS INFLUENCING THE RECOVERY OF SYMPATHOMIMETICS [J].
BRANDTS, PM ;
MAES, RAA ;
LEFERINK, JG ;
DELIGNY, CL ;
NIEUWDORP, GHE .
ANALYTICA CHIMICA ACTA, 1982, 135 (01) :85-98
[3]   ANALYSIS OF TERBUTALINE IN BIOLOGICAL-FLUIDS BY GAS-CHROMATOGRAPHY ELECTRON-IMPACT MASS-SPECTROMETRY [J].
CLARE, RA ;
DAVIES, DS ;
BAILLIE, TA .
BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (01) :31-37
[4]  
COURTHEYN D, COMMUNICATION
[5]   DETERMINATION OF CLENBUTEROL IN THE HIGH NANOGRAM RANGE IN PLASMA OF MICE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
DIQUET, B ;
DOARE, L ;
SIMON, P .
JOURNAL OF CHROMATOGRAPHY, 1984, 336 (02) :415-421
[6]   HPLC ANALYSIS OF CLENBUTEROL, A BETA-ADRENERGIC DRUG, IN EQUINE URINE [J].
EDDINS, C ;
HAMANN, J ;
JOHNSON, K .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (07) :308-312
[7]  
EDHOLM LE, 1984, EUR J RESPIR DIS, V65, P33
[8]   DETERMINATION OF DRUG ENANTIOMERS IN BIOLOGICAL SAMPLES BY COUPLED COLUMN LIQUID-CHROMATOGRAPHY AND LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
EDHOLM, LE ;
LINDBERG, C ;
PAULSON, J ;
WALHAGEN, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (01) :61-72
[9]   DETERMINATION OF ALBUTEROL IN HUMAN-SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
EMM, T ;
LESKO, LJ ;
LESLIE, J ;
PERKAL, MB .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (01) :188-194
[10]   QUANTITATION OF CLENBUTEROL IN BIOLOGICAL-FLUIDS USING AMMONIA CI AND AUTOMATED CAPILLARY GCMS [J].
FORSTER, HJ ;
ROMINGER, KL ;
ECKER, E ;
PEIL, H ;
WITTROCK, A .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (05) :417-420