EFFECTS OF HIP CENTER LOCATION ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES

被引:128
作者
DELP, SL
MALONEY, W
机构
[1] NORTHWESTERN UNIV, DEPT BIOMED ENGN, CHICAGO, IL 60611 USA
[2] NORTHWESTERN UNIV, DEPT REHABIL MED, CHICAGO, IL 60611 USA
[3] PALO ALTO MED CLIN, PALO ALTO, CA 94301 USA
关键词
D O I
10.1016/0021-9290(93)90011-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have developed a three-dimensional biomechanical model of the human lower extremity to study how the location of the hip center affects the moment-generating capacity of four muscle groups: the hip abductors, adductors, flexors, and extensors. The model computes the maximum isometric force and the resulting joint moments that each of 25 muscle-tendon complexes develops at any body position. Abduction, adduction, flexion, and extension moments calculated with the model correspond closely with isometric joint moments measured during maximum voluntary contractions. We used the model to determine (1) the hip center locations that maximize and minimize the moment-generating capacity of each muscle group and (2) the effects of superior-inferior, anterior-posterior, and medial-lateral displacement of the hip center on the moment arms, maximum isometric muscle forces, and maximum isometric moments generated by each muscle group. We found that superior-inferior displacement of the hip center has the greatest effect on the force- and moment-generating capacity of the muscles. A 2 cm superior displacement decreases abduction force (44%), moment arm (12%), and moment (49%), while a 2 cm inferior displacement increases abduction force (20%), moment arm (7%) and moment (26%). Similarly, a 2 cm superior displacement decreases flexion force (27%), moment arm (6%), and moment (22%), while inferior displacement increases all three variables. Anterior-posterior displacement alters the moment-generating capacity of the flexors and extensors considerably, primarily due to moment arm changes. Medial-lateral displacement has a large effect on the moment-generating capacity of the adductors only. A 2 cm medial displacement decreases adduction moment arm (20%), force (26%) and moment (40%). These results demonstrate that the force- and moment-generating capacities of the muscles are sensitive to the location of the hip center.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 41 条
[31]  
RYSER DK, 1988, ARCH PHYS MED REHAB, V69, P840
[32]   RELATIVE STRENGTH OF HAMSTRINGS DURING HIP EXTENSION [J].
WATERS, RL ;
PERRY, J ;
MCDANIELS, JM ;
HOUSE, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (08) :1592-1597
[33]   ECCENTRIC AND CONCENTRIC TORQUE-VELOCITY CHARACTERISTICS OF THE QUADRICEPS FEMORIS IN MAN [J].
WESTING, SH ;
SEGER, JY ;
KARLSON, E ;
EKBLOM, B .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1988, 58 (1-2) :100-104
[34]   EFFECTS OF ELECTRICAL-STIMULATION ON ECCENTRIC AND CONCENTRIC TORQUE VELOCITY RELATIONSHIPS DURING KNEE EXTENSION IN MAN [J].
WESTING, SH ;
SEGER, JY ;
THORSTENSSON, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 140 (01) :17-22
[35]   MUSCLE ARCHITECTURE OF THE HUMAN LOWER-LIMB [J].
WICKIEWICZ, TL ;
ROY, RR ;
POWELL, PL ;
EDGERTON, VR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (179) :275-283
[36]  
WILLIAMS PE, 1978, J ANAT, V127, P459
[37]  
Winter D., 2009, BIOMECHANICS MOTOR C, VFourth
[38]  
Winter D.A., 1990, MULTIPLE MUSCLE SYST, P534, DOI DOI 10.1007/978-1-4613-9030-5_33
[39]   A PLANAR MODEL OF THE KNEE-JOINT TO CHARACTERIZE THE KNEE EXTENSOR MECHANISM [J].
YAMAGUCHI, GT ;
ZAJAC, FE .
JOURNAL OF BIOMECHANICS, 1989, 22 (01) :1-10
[40]  
YODER SA, 1988, CLIN ORTHOP RELAT R, V228, P79