TIME-RESOLVED LUMINESCENCE DETECTION OF EUROPIUM(III) CHELATES IN CAPILLARY ELECTROPHORESIS

被引:19
作者
LATVA, M [1 ]
ALAKLEME, T [1 ]
BJENNES, H [1 ]
KANKARE, J [1 ]
HAAPAKKA, K [1 ]
机构
[1] UNIV TURKU,DEPT CHEM,SF-20500 TURKU,FINLAND
关键词
CAPILLARY ELECTROPHORESIS; TIME-RESOLVED LUMINESCENCE DETECTION; LUMINESCENT EUROPIUM(III) CHELATES;
D O I
10.1039/an9952000367
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An instrumentally simple on-column time-resolved luminescence capillary electrophoresis (CE) detector for determining and characterizing migrated europium(III) chelates on the basis of their long-lived D-5(0) --> F-7-multiplet transitions has been constructed. In addition to the background fluorescence arising from the cell walls, this time-resolved luminescence method of measurement also allows an efficient discrimination of the analyte emission against the short-lived background fluorescence caused by possible fluorescent impurities in the electrophoresis buffer; this should provide a feasible means of constructing a CE detector for the trace analysis of europium(III) chelates and also of samples of biological interest labelled with europium(III) chelates, If supplied additionally with a device for determining the excited-state lifetimes of separated europium(III) chelates, this time-resolved luminescence detector should make possible the peak identification of migrated europium(III) chelates.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 47 条
[1]   USE OF A DOUBLE-DETECTOR SYSTEM FOR THE MEASUREMENT OF MOBILITIES IN ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
VERHEGGEN, TPEM ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :591-600
[2]   CAPILLARY ZONE ELECTROPHORESIS WITH ANALYTE VELOCITY MODULATION - APPLICATION TO REFRACTIVE-INDEX DETECTION [J].
CHEN, CY ;
DEMANA, T ;
HUANG, SD ;
MORRIS, MD .
ANALYTICAL CHEMISTRY, 1989, 61 (14) :1590-1593
[3]  
Chevret J. P., 1991, J CHROMATOGR, V543, P439
[4]   EUROPIUM CHELATE LABELS IN TIME-RESOLVED FLUORESCENCE IMMUNOASSAYS AND DNA HYBRIDIZATION ASSAYS [J].
DIAMANDIS, EP ;
CHRISTOPOULOS, TK .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :A1149-+
[5]   VARIABLE-WAVELENGTH ON-COLUMN FLUORESCENCE DETECTOR FOR OPEN-TUBULAR ZONE ELECTROPHORESIS [J].
GREEN, JS ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :337-343
[6]  
HARJU R, 1981, WALLAC REPORT
[7]  
Hemmila I. A., 1991, APPLICATIONS FLUORES
[8]   LASER-INDUCED FLUORESCENCE AND FLUORESCENCE MICROSCOPY FOR CAPILLARY ELECTROPHORESIS ZONE DETECTION [J].
HERNANDEZ, L ;
ESCALONA, J ;
JOSHI, N ;
GUZMAN, N .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :183-196
[9]   LANTHANIDE ION LUMINESCENCE PROBES OF THE STRUCTURE OF BIOLOGICAL MACROMOLECULES [J].
HORROCKS, WD ;
SUDNICK, DR .
ACCOUNTS OF CHEMICAL RESEARCH, 1981, 14 (12) :384-392
[10]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192