TIME-RESOLVED LUMINESCENCE DETECTION OF EUROPIUM(III) CHELATES IN CAPILLARY ELECTROPHORESIS

被引:19
作者
LATVA, M [1 ]
ALAKLEME, T [1 ]
BJENNES, H [1 ]
KANKARE, J [1 ]
HAAPAKKA, K [1 ]
机构
[1] UNIV TURKU,DEPT CHEM,SF-20500 TURKU,FINLAND
关键词
CAPILLARY ELECTROPHORESIS; TIME-RESOLVED LUMINESCENCE DETECTION; LUMINESCENT EUROPIUM(III) CHELATES;
D O I
10.1039/an9952000367
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An instrumentally simple on-column time-resolved luminescence capillary electrophoresis (CE) detector for determining and characterizing migrated europium(III) chelates on the basis of their long-lived D-5(0) --> F-7-multiplet transitions has been constructed. In addition to the background fluorescence arising from the cell walls, this time-resolved luminescence method of measurement also allows an efficient discrimination of the analyte emission against the short-lived background fluorescence caused by possible fluorescent impurities in the electrophoresis buffer; this should provide a feasible means of constructing a CE detector for the trace analysis of europium(III) chelates and also of samples of biological interest labelled with europium(III) chelates, If supplied additionally with a device for determining the excited-state lifetimes of separated europium(III) chelates, this time-resolved luminescence detector should make possible the peak identification of migrated europium(III) chelates.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 47 条
[41]   RETENTION OF IONIC AND NON-IONIC CATECHOLS IN CAPILLARY ZONE ELECTROPHORESIS WITH MICELLAR SOLUTIONS [J].
WALLINGFORD, RA ;
EWING, AG .
JOURNAL OF CHROMATOGRAPHY, 1988, 441 (02) :299-309
[42]   SEPARATION OF SEROTONIN FROM CATECHOLS BY CAPILLARY ZONE ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION [J].
WALLINGFORD, RA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :98-100
[43]   CHARACTERIZATION OF A MICROINJECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
WALLINGFORD, RA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :678-681
[44]   NANOLITER-SCALE MULTIREFLECTION CELL FOR ABSORPTION DETECTION IN CAPILLARY ELECTROPHORESIS [J].
WANG, TS ;
AIKEN, JH ;
HUIE, CW ;
HARTWICK, RA .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1372-1376
[45]   ADJUSTABLE APERTURE-WIDTH DETECTOR CELL FOR ON-COLUMN DETECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
WANG, TS ;
HARTWICK, RA ;
CHAMPLIN, PB .
JOURNAL OF CHROMATOGRAPHY, 1989, 462 :147-154
[46]   PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS [J].
WU, NA ;
HUIE, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02) :309-315
[47]   AXIAL-BEAM ABSORPTION DETECTION FOR CAPILLARY ELECTROPHORESIS WITH A CONVENTIONAL LIGHT-SOURCE [J].
XI, XB ;
YEUNG, ES .
APPLIED SPECTROSCOPY, 1991, 45 (07) :1199-1203