PHASED-ARRAY COILS FOR UPPER EXTREMITY MRA

被引:12
作者
MONROE, JW [1 ]
SCHMALBROCK, P [1 ]
SPIGOS, DG [1 ]
机构
[1] OHIO STATE UNIV,DEPT RADIOL,MRI FACIL,COLUMBUS,OH 43210
关键词
MAGNETIC RESONANCE ANGIOGRAPHY; PHASED ARRAY RF COILS; UPPER EXTREMITY;
D O I
10.1002/mrm.1910330212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A phased array coil was constructed for imaging the upper extremity vasculature for patients undergoing dialysis treatment. The phased array coil exhibits improved signal-to-noise ratio (SNR) over the body coil and allows imaging of the entire upper extremity. SNR as a function of depth was measured on a homogeneous phantom with the arm coil and compared with the body coil. Near the coil there is an improvement of a factor of 7 and at a depth of approximately 6-7 cm, there is an improvement of factor 2. In vivo SNR measurements resulted in similar improvements. Images of the upper extremity vasculature of healthy volunteers were generated using 2D-time-of-flight (2DTOF) angiography. Blood flow velocity was assessed in a CINE-phase contrast study.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 10 条
[1]   HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS [J].
DOUSSET, V ;
GRENIER, N ;
DOUWS, C ;
SENUITA, P ;
SASSOUSTE, G ;
ADA, L ;
POTAUX, L .
RADIOLOGY, 1991, 181 (01) :89-94
[2]   IMAGING OF HEMODIALYSIS FISTULAS - LIMITATIONS OF MR ANGIOGRAPHY [J].
GEHL, HB ;
BOHNDORF, K ;
GLADZIWA, U ;
HANDT, S ;
GUNTHER, RW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :271-275
[3]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[4]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[5]  
HOLDER LE, 1993, HAND CLIN, V9, P85
[6]  
KRAPAN D, 1991, INT J ARTIF ORGANS, V14, P78
[7]   THE USE OF A DIASONICS DRF400 DUPLEX ULTRASOUND SCANNER TO MEASURE VOLUME FLOW IN ARTERIOVENOUS-FISTULAS IN PATIENTS UNDERGOING HEMODIALYSIS - AN ANALYSIS OF MEASUREMENT UNCERTAINTIES [J].
OATES, CP ;
WILLIAMS, ED ;
MCHUGH, MI .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) :571-579
[8]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225
[9]  
SCHMALBROCK P, IN PRESS J COMPUT AS
[10]  
STEPHENSON HE, 1971, ARCH SURG-CHICAGO, V103, P774