BIOLOGICAL MONITORING OF HEXAMETHYLENE DIISOCYANATE BY DETERMINATION OF 1,6-HEXAMETHYLENE DIAMINE AS THE TRIFLUOROETHYL CHLOROFORMATE DERIVATIVE USING CAPILLARY GAS-CHROMATOGRAPHY WITH THERMOIONIC AND SELECTIVE-ION MONITORING

被引:16
作者
DALENE, M [1 ]
SKARPING, G [1 ]
TINNERBERG, H [1 ]
机构
[1] UNIV LUND HOSP,DEPT OCCUPAT & ENVIRONM MED,S-22185 LUND,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 656卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00137-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A GC method using a novel derivatization reagent, 2',2',2-trifluoroethyl chloroformate (TFECF), for the derivatization of primary and secondary aliphatic amines with the formation of carbamate esters is presented. The method is based on a derivatization procedure in a two-phase system, where the carbamate ester is formed. The method is applied to the determination of 1,6-hexamethylene diamine (HDA) in aqueous solutions and human urine, using capillary GC. Detection was performed using thermionic specific detection (TSD) and mass spectrometry (MS)-selective-ion monitoring (SIM) using electron-impact (EI) and chemical ionization (CI) with ammonia monitoring both positive (CI)(+) and negative ions (CI)(-). Quantitative measurements were made in the chemical ionization mode monitoring both positive and negative ions. Tetra-deuterium-labelled HDA (TDHDA; (H2NCH2)-H-2(CH2)(4)(CH2NH2)-H-2) was used as the internal standard for the GC-MS analysis. In CI+ the m/z 386 and the m/z 390 ions corresponding to the [M + 18](+) ions (M = molecular ion) of HDA-TFECF and TDHDA-TFECF were measured; in CI- the m/z 267 and the m/z 271 ions corresponding to the [M - 101](-) ions. The overall recovery was found to be 97 +/- 5% for a HDA concentration of 1000 mu g/l in urine. The minimal detectable concentration in urine was found to be less than 20 mu g/l using GC-TSD and 0.5 mu g/l using GC-SIM. The overall precision for the work-up procedure and GC analysis was ca. 3% (n = 5) for 1000 mu g/l HDA-spiked urine, and ca. 4% (n = 5) for 100 mu g/l. The precision using GC-SIM for urine samples spiked to a concentration of 5 mu g/l was found to be 6.3% (n = 10).
引用
收藏
页码:319 / 328
页数:10
相关论文
共 10 条
[1]  
BERODE M, 1992, THESIS U LAUSANNE, pCH5
[2]   BIOLOGICAL MONITORING OF ISOCYANATES AND RELATED AMINES .1. DETERMINATION OF 1,6-HEXAMETHYLENE DIAMINE (HDA) IN HYDROLYZED HUMAN-URINE AFTER ORAL-ADMINISTRATION OF HDA [J].
BRORSON, T ;
SKARPING, G ;
SANDSTROM, JF ;
STENBERG, M .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1990, 62 (01) :79-84
[3]   BIOLOGICAL MONITORING OF ISOCYANATES AND RELATED AMINES .2. TEST CHAMBER EXPOSURE OF HUMANS TO 1,6-HEXAMETHYLENE DIISOCYANATE (HDI) [J].
BRORSON, T ;
SKARPING, G ;
NIELSEN, J .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1990, 62 (05) :385-389
[4]   CHROMATOGRAPHIC DETERMINATION OF AMINES IN BIOLOGICAL-FLUIDS WITH SPECIAL REFERENCE TO THE BIOLOGICAL MONITORING OF ISOCYANATES AND AMINES .4. DETERMINATION OF 1,6-HEXAMETHYLENEDIAMINE IN HUMAN URINE USING CAPILLARY GAS-CHROMATOGRAPHY AND SELECTIVE ION MONITORING [J].
DALENE, M ;
SKARPING, G ;
BRORSON, T .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :405-413
[5]  
DALENE M, 1987, THESIS LUND U
[6]  
KENNEDY AL, 1992, ISOCYANATES LUNG DIS, V7, P301
[7]   DETERMINATION IN URINE OF DIISOCYANATE-DERIVED AMINES FROM OCCUPATIONAL EXPOSURE BY GAS-CHROMATOGRAPHY MASS FRAGMENTOGRAPHY [J].
ROSENBERG, C ;
SAVOLAINEN, H .
ANALYST, 1986, 111 (09) :1069-1071
[8]   TRACE ANALYSIS OF AIRBORNE 1,6-HEXAMETHYLENEDIISOCYANATE AND THE RELATED AMINOISOCYANATE AND DIAMINE BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY [J].
SKARPING, G ;
DALENE, M ;
MATHIASSON, L .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (03) :453-468
[9]   DETERMINATION OF PIPERAZINE IN WORKING ATMOSPHERE AND IN HUMAN-URINE USING DERIVATIZATION AND CAPILLARY GAS-CHROMATOGRAPHY WITH NITROGEN-SELECTIVE AND MASS-SELECTIVE DETECTION [J].
SKARPING, G ;
BELLANDER, T ;
MATHIASSON, L .
JOURNAL OF CHROMATOGRAPHY, 1986, 370 (02) :245-258
[10]   CHROMATOGRAPHIC DETERMINATION OF AMINES IN BIOLOGICAL-FLUIDS WITH SPECIAL REFERENCE TO THE BIOLOGICAL MONITORING OF ISOCYANATES AND AMINES .1. DETERMINATION OF 1,6-HEXAMETHYLENEDIAMINE USING GLASS-CAPILLARY GAS-CHROMATOGRAPHY AND THERMIONIC SPECIFIC DETECTION [J].
SKARPING, G ;
DALENE, M ;
BRORSON, T ;
SANDSTROM, JF ;
SANGO, C ;
TILJANDER, A .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (01) :125-133